Charging Instructions - Battery Watering Technologies Aqua Sub Jr. NC5090PN Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Charging Instructions:

Charge the battery for 4 before using the tank for the first time or if it has been stored more
than 6 months to ensure the unit is fully charged.
1.
Turn the power switch on the handle to the "OFF" position.
2.
Remove the battery from the bottom of the back plate by pushing the release button and
pulling down.
3.
Plug the charger into the top of the battery pack.
4.
Plug the charger into 100-240 VAC 50/60 Hz volt power supply. (You may need a plug
adapter if outside the U.S)
5.
While charging, the light will appear red. The light will change to green when fully charged.
Disconnect the battery pack from the charger and the charger from the electrical outlet.
6.
Insert the battery pack into the open dock at the bottom of the back panel, a click will be
herard when properly attached.
Troubleshooting:
Pump will NOT run:
1.
Make sure the on/off switch is in the "ON" position (power switch is located on the handle
of the unit).
2.
Make sure the battery pack is fully charged.
3.
Check the in-line fuse on the wires on the pump (located behind back cover). If blown,
replace with new fuse (5 Amp mini-blade fuse).
Pump runs, but does not prime:
1.
Inspect to make sure water is above inlet hole.
2.
Inspect hose to be sure there are no kinks or blockages.
Maintenance:
Please utilize strainer to prevent debris from getting into the pump.
Warranty
This product is warranted against defects in workmanship and materials for a period of one year
from date of shipment.
CAUTION: If storing this product in
freezing conditions, drain all of the
water to prevent damage.