The Filling Set is installed as temporary connection to fill sealed
heating systems.
De vulset wordt geïnstalleerd als tijdelijke aansluiting om verzegelde
verwarmingsinstallaties te vullen.
Le groupe de remplissage consiste en une connexion temporaire
permettant de remplir les installations de chauffage hermétiques.
300604 CST
Max. Working Pressure:
Max. Working Temperature:
Flexible hose length:
Max. werkingsdruk:
Maximale werkingstemperatuur:
Lengte slang
Pression maxi d'exercice:
Température maximale d'exercice:
Longueur flexible:
1/2"
x 1/2"
1
38726
GB
NL
F
3006 series
10 bar
40°C
400 mm
10 bar
40°C
400 mm
10 bar
40°C
400 mm

Publicité

loading

Sommaire des Matières pour CALEFFI 3006 Serie

  • Page 1 www.c leffi.com 38726 Filling set for heating systems Vulset voor verwarmingsinstallaties Groupe de remplissage pour installations de chauffage © opyright 2010 alef fi 3006 series Funzione The Filling Set is installed as temporary connection to fill sealed heating systems. Werking Fonction De vulset wordt geïnstalleerd als tijdelijke aansluiting om verzegelde verwarmingsinstallaties te vullen.
  • Page 2 Application scheme The Filling Set comprises: Toepassingsschema 1) Ball shut-off valve Ø 1/2” M x 3/8” F Schéma d’application 2) Gasket 3) Backflow preventer Ø 3/8” M x Ø 1/2” M 4) One 400 mm flexible hose with compression fittings and “O” ring seals (Do not overtighten for ease of connection and removal) 5) Ball shut-off valve Ø...
  • Page 3 Installazione 1. The filling loop must be installed in close proximity to the boiler. Installatie 2. Ensure order of installation as indicated on the application scheme. Installation 3. Ensure that the distance between the backflow preventer (3) and isolating valve (5) does not exceed the length of the flexible hose. 4.
  • Page 4 Safety The Filling Set must be installed by a licensed plumber in accordance with Veiligheid national regulations and/or relevant local requirements. Sécurité If the Filling Set is not installed, commissioned and maintained properly, according to the instructions contained in this manual, it may not operate correctly and may endanger the user.

Ce manuel est également adapté pour:

300604 cst