Operation

LED Indicators

LED (Color)
Normal Operation
Bulk/Accept (Yellow)
Charging/Float (Green) LED
Abnormal Operation
Error (Red)
Notes:
• Battery voltage selection cannot be changed during charging; the battery must be disconnected before selecting the charger voltage.
• The battery is fully charged when the green LED is illuminated. You can stop charging the battery at this point or keep it connected in floating status.
• To end a charging session, disconnect the AC power cord from the source, then disconnect the charger's clamps from the battery terminals.

Mounting (Optional)

The 4-in-1 Charger can be mounted to a horizontal surface. To
mount, install four fasteners (not included) through the charger's
mounting slots into a rigid surface. Secure the fasteners as far
back in the mounting slots as possible, otherwise the fasteners
may loosen and cause the charger to slide back and forth.
Note: The user is responsible for determining if the hardware and mounting
surface are suitable to support the charger.
LED Status
Operation Status
Solid
Soft start
Slow flash
Bulk constant current charging
Fast flash
Absorption constant voltage charging
Very fast flash
Finish constant voltage charging
Slow flash
Floating
Fast flash
Floating
Flash 2x
Charger cannot connect to battery or broken
DC fuse
Flash 3x
Battery voltage is too high or too low
Flash 4x
Shorted internal thermal sensor or open circuit
Flash 5x
Internal overheat protection
Description/Solution
Current is charging slowly
Battery drawing maximum charge current
Battery reaches set voltage limit; adjusts to draw
less charge current
Battery near 100% capacity; approaching
floating status
Battery charge full
Battery charge full and floating current < 0.5 A
Check fuse and replace if broken
Check that battery voltage selected on charger
matches battery's voltage
Defective thermal sensor; follow the Service
instructions on the next page
Unit cooling down; will automatically restart upon
reaching average internal operating temperature