1
Position the body of the concealed set
and mark where the connections are to be
installed.
3
When the circuit has been installed, connect
the concealed body, ensuring that the water
supply is still disconnected. The body will be
supported by the connections.
Before hiding the piping in the wall, assure that the concealed mixer body is alienated, working
properly, observing no communication between the different water outlets and not leaking points.
14
3 ways
2
Make the necessary channels and the space
for the housing if the set is to be embedded in
a brick wall.
Pay attention to the mark that indicates the
distance at which the covering plate must be
flush fitted (Fig 3).
Take tile thickness into account.
4
After installing the body, fill in the channels
leaving the Porex covering the body as
protection.