Technical Data

Explosion safety category:
Protection against ignition:
Conformity:
Standards applied:
Ambient temperature:
Material housing:
Material lens:
Dimensions:
Mounting:
Light source:
Voltage:
Input voltage:
Ingress protection level:
Mounting position:
Duration of use:
Circumstances of use:
Electrical connection:
Earth connection:
Weight:
6.

Marking

The signal lights comply to the European Directives for EMC and ATEX and implicit to the
Low Voltage Directive. With regard to explosion safety the signal lights have been designed
and manufactured on the basis of the essential health and safety requirements of European
Directive 2014/34/EU (ATEX 114) relating to Group II Category 3GD. Harmonized European
construction standards have been applied fulfilling the essential requirements of the
directives. Please refer to chapter 5 'Technical data" and the EU Declaration of Conformity at
the last page of this user manual for more details.
Installation manual AR-047 LED signal light
ATEX II 3GD
Ex mc IIC T4 Gc, Ex mc IIIC T135°C Dc
European Directive 2014/34/EU (ATEX 114),
2014/30/EU (EMC)
EN 60079-0:2018 and EN 60079-18:2015 / A1:2017
-20 ˚C to +60 ˚C
AISI 316 stainless steel or anodized aluminum
20 mm impact-resistant Polycarbonate
Ø 95 x 60 mm (excl. cable gland)
Stainless steel bracket included
15 LEDs
24 VDC ± 10%
160 mA @ 24 VDC
IP 65 according to EN 60529
As desired (360º)
Continuous
Exterior and interior use
Fixed cable, 4 x 0,75 mm², length 5 m
External, stainless steel, 4 mm²
1.750 g (stainless steel), 930 gram (aluminum)