5 - PROGRAMMING
Remove the power before to pick - up the
!
protection plexiglass and operate on the
terminal blocks.
The operating mode of the radio-programmer is selected with the
6-ways binary dip-switch ( Fig. 13.)
PV
LV
ON
OFF
Operating mode selection
NOTE: The use of the Man present mode causes a faster
consumption of the transmitter battery.
Operating mode Dip-switch 1-5 Dip-switch 6
SEQUENTIAL
( CYCLIC )
MIXED
MAN PRESENT
Operating time selection during the sequential and
mixed mode
By positioning the dip-switches 1 to 5 on ON, during the operating
modes sequential and mixed, it is possible to select the time-out of the
motor.
Switch 1 =
6 seconds
Switch 2 =
12 seconds
Switch 3 =
24 seconds
Switch 4 =
48 seconds
Switch 5 =
96 seconds
Multiple switches positioned on ON position causes the sum of the
resulting time.
Command type setting
Local command
The transmitter strored on PR allow to operate in sequential, mixed
or man present mode and by pushing only one key of the
transmitter for all the movements (opening, stop and closing).
Pag. 8
PR
LR
1 2 3 4 5 6
ON
1
2
3
4
5
6
According
selected time
According
selected time
OFF
General command
It is necessary to have a 4 keys transmitter of the same series
The transmitters stored on PV allow to operate in sequential mode
but need 3 keys, a key (B) to open a key (D) to close and a key (C)
to stop.
During the movement (opening or closing) only the stop key (C) is
enabled
!
6 - TRANSMITTER CODES MEMORISATION
Fig. 8
The transmitter key code can be stored onto the radioprogrammer
in 2 ways:
A / B - Using the radioprogrammer push-buttons PR and PV
C / D - In self-learning mode, far from the appliance, using the
transmitter keys.
A - Local command using PR
1) Push and keep pushed the button PR of the receiver until the led LR
switches on;
2) Within 4 seconds push the key of the transmitter to memorise.
The red led LR will switch off.
3) Repeat the same procedure for each transmitter key.
B - General command using PV
ON
It is necessary to have a 4 key transmitter of the same range
1) Push and keep pushed the button PV of the receiver until the green
led LV switches on;
OFF
2) Within 4 seconds push the key D of the transmitter to
memorise.
3) The green led LV will switches off and the motor relay will
activate for a while.
OFF
The D key will make the closing of the motor.
The activation of the remaining transmitter keys is automatic, by
correlating the key B to the opening and the key C to the stop.
C - Local command using the keys of the transmitter
1) Push and keep pushed simultaneously the keys A and B of the
TX : LR and LV will flash and the buzzer makes a bip.
2) Push the key A of the same TX for 4 sec. until the led LV switches on
and the buzzer emits a long bip =Biiiiiiip, then release the key.
3) Before the end of the bip ( about within 2 sec.) push again the key A
of the TX : LR will switch off.
D - General command using the keys of the
transmitter
1) Push and keep pushed simultaneously the keys A and B of the TX :
LR and LV will flash and the buzzer makes a bip.
2) Push the key B of the same TX for 4 sec. until the led LV start to blink
and the buzzer makes bip, bip, bip,..,bip. then release the key.
3) Before the end of the bip ( about within 2 sec.) push the key D of the
TX : LV will switch off.
NOTE 1 : The memorization of the remaining transmitter key is
In order to be sure of the complete drive of all
the receivers, it is advisable to use the
transmitter at the minimum distance (do not
use over 20m)

Publicité