Technical Specifications - Erone 400W Plus Notice D'installation Et Utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1 - INTRODUCTION
The receiver ERONE 400 W PLus is a radio programmer which
can drive directly an asynchronous 230 Vac AC motor with max
power of 400 W. The operating frequency is 433,92 Mhz and the
and the coding system is Keeloq
SERIES
TYPE
024A
S2TR2641E2
024A
S2TR2641E4
MINI
SETR2641AM2
WALL TYPE
SETR2641-TM

2 - TECHNICAL SPECIFICATIONS

Type
Receiver type
Carrier frequency
Local oscillator frequency
Modulation
Input load
Channel width
Intermediate frequency
Input sensitivity
Local oscillator emissions
Power voltage
Motor maximum power
Memory capacity
Coding system
Operating temperature
IP grade
Weight
Overall dimensions
3 - FUNCTIONALITY
Sequential (or cyclic):
1 Pulse opens
1 Pulse closes, stop with a timer
Mixed
1 Pulse opens, closing only with permanent contact.
Man present:
Opening and closing only with permanent contact (reduced
range). The motor time-out is selectable (from 6 to 186 sec) by
means of 5 dip - switches; it is used as security to avoid powering
the motor for too long after the mechanical stop.
Other features:
Local and general operating selection (with multiple motor
driving); the general command is possible only for the sequential
operating mode.
For the general mode using it is necessary to use a 4 keys
transmitter of the same range.
It possible to connect an external push button or a key - contact to
complete the radiocontrol.
The memory capacity is 85 transmitters.
ENGLISH
®
Hopping code
FREQUENCY CODING
433.92 MHz Rolling code
433.92 MHz Rolling code
433.92 MHz Rolling code
433.92 MHz Rolling code
SEL 2641R433-P4P
Superheterodyne
433,92 MHz
6,6128 MHz
AM/ASK
50 Ohm
> 25 KHz
10,7 MHz
-115 dBm
< -57 dBm
230 Vac
400 W
85
Keeloq® Hopping code
-20°/+70°C
IP44
380 gr.
140 x 115 x 52 mm
4 - INSTALLATION
Positioning
The local choice is very impotant for the best result of the installation.
The following conditions have to be followed:
- Fix the radioprogrammer far from the interference sources as
informatic systems, alarm systems or other radio emissions.
- The distance between 2 receivers should be greater of 1.5 mt.
Fixing
Remove the cover of the receiver; fix the box in each corner by
using the screws and the plugs supplied.
Connections
1- Connect the power supply (230 Vac) to the terminal blocks (fig.
10):
terminal 1 = PH phase
terminal 2 = N neutral
terminal 6 = earth
1
2
Ph
N
2 - Connect the motor to the terminal blocks (fig. 11):
terminal 3 = C common
terminal 4 = O open
terminal 5 = CL close
terminal 7 = GND ground
Connect the capacitor between terminals 4 and 5.
3 -Connect the accessories as follows (fig. 12):
- if you want to use an aerial, (not supplied), connect the shield to the
terminal 10, and the net to the terminal 11; otherwise if you use the
aerial cable supplied, connect it to the terminal 11.
- if you want to connect an external command device (not supplied),
connect the N. O. contact to the terminals 8 and 9;
NOTE2:The led L1 switches on when the N.A. contact of the external
command is activated.
6
3
4
5
7
C O CL
Led L1
8
9
10
11
Fig.10
Fig. 11