Health Zenith SL-5676 Mode D'installation page 2

Luminaire mural crépusculeaurore au sodium haute pression
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Ballast Assembly Replacement Instructions
Ballast assembly can be replaced without the
cutting of any wires. Use of a qualifi ed electrician is
recommended.
WARNING: Turn power off at the fuse or circuit
breaker.
1. Remove plastic cover.
2. Remove bulb.
3. Remove two screws holding ballast cover (white, metal box with
light socket in it).
4. Remove tape from wire bundle. Be careful not to damage wires.
5. Label wires according to wiring diagram.
6. Remove wire nuts from wires. Retain wire nuts to connect replace-
ment ballast assembly.
7. Remove two long screws and bracket holding ballast in place.
8. Dispose of used ballast assembly.
9. Connect the replacement ballast assembly following steps 1 through
7 in reverse order.
Ballast Cover
Lamp Socket
Note: Refl ector is not shown for clarity.
Red
Socket
Red
Blue
Ballast
Ballast Retention Screw
Lock Washer
Ignitor
Lamp
White
White
Blue
Ignitor
Ballast Retention Bracket
Ballast
Aluminum Fixture
Photocell
Socket
120V AC
Input
Housing
598-1222-02