3.6.4 Fitting instructions
!
The product should be filled with water before the power is switched on.
Fixed electric fittings should be used for installation in new homes or when changing an
!
existing electrical setup in accordance with regulations. A mains cable with plug for wall
socket can be used when replacing the product without changing the electrical setup.
!
The mains cable should withstand 90°C. A strain reliever must be fitted.
The product must have a clearance for servicing of 40 cm in front of the cover / 10 cm
!
over the mixer valve.
In case of damage to the mains cable and plug, it should be replaced with a specially
!
adapted mains cable from the manufacturer.
3.6.5 Fitting recommendation
The mains cable supplied should be used with fixed electric fittings by removing the plug for
-
the wall socket. (Heat-resistant)
Mains cable for wall socket/wall box should be hidden under one of the channels in the bot-
-
tom of the product.
For products with ≤ 2kW capacity, a > 10A fuse / > 1.5# wire should be used*.
For products with ≤ 3kW capacity, a > 15A fuse / > 2.5# wire should be used*.
-
For products with ≤ 5kW capacity, the power supply should be specified according to NEK 400*.
*This product is described with an output of
2+2, 3+3 or 5+5 kW. This states that the prod-
uct is fitted with two elements each with the
stated output, but the product never draws
Electrical connection, diagram 5+5 kW
WARNING
!
!
CAUTION
RECOMMENDATION
more than 2, 3 or 5 kW respectively as the
power supply is swiched between the two ele-
ments as needed. The two elements will never
be connected at the same time.