Product Information; Declaration Of Conformity; Scope Of Delivery; Product Dimensions And Minimum Clearances - Bosch Climate 3000i Serie Notice D'installation

Masquer les pouces Voir aussi pour Climate 3000i Serie:
Table des Matières

Publicité

Product Information

2
Product Information
2.1

Declaration of conformity

The design and operating characteristics of this product comply with the
European and national requirements.
The CE marking declares that the product complies with all the
applicable EU legislation, which is stipulated by attaching this
marking.
The complete text of the Declaration of Conformity is available on the
Internet: worcester-bosch.co.uk.
2.2

Scope of delivery

Key to Fig. 1:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Cold catalyst filter
[4]
Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket)
[5]
Remote control
[6]
Remote control holder with fixing screw
[7]
Fixing materials (5 screws and 5 wall plugs)
[8]
Set of printed documents for product documentation
[9]
5-core communication cable (optional accessory)
[10] 4 anti-vibration couplings for the outdoor unit
2.3

Product dimensions and minimum clearances

2.3.1

Indoor unit and outdoor unit

Figures 2 to 4.
2.3.2

Refrigerant pipes

Key to Fig. 5:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
If the outdoor unit is positioned higher than the indoor unit, install a
siphon-shaped elbow on the gas side after no more than 6 m and every
6 m thereafter ( Fig. 5, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Maximum pipe
length
CL3000i 26 E
CL3000i 35 E
CL3000i 53 E
CL3000i 70 E
1) Gas side or liquid side
2) Measured from bottom edge to bottom edge.
Table 2 Pipe length and difference in height
Unit type
Liquid side [mm]
CL3000i 26 E
6.35 (1/4")
CL3000i 35 E
6.35 (1/4")
CL3000i 53 E
6.35 (1/4")
CL3000i 70 E
9.53 (3/8")
Table 3 Pipe diameter depending on appliance type
56
Maximum difference
1)
2)
[m]
in height
[m]
≤ 25
≤ 10
≤ 25
≤ 10
≤ 30
≤ 20
≤ 50
≤ 25
Pipe size
Gas side [mm]
9.53 (3/8")
9.53 (3/8")
12.7 (1/2")
15.9 (5/8")
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
12.7 (1/2")
15.9 (5/8")
Table 4 Alternative pipe diameter
Specification of the pipes
Min. piping length
Standard piping length
Additional refrigerant if the pipe length
exceeds 5 m (liquid side)
Pipe thickness with 6.35 mm to 12.7 mm
pipe diameter
Pipe thickness with 15.9 mm pipe
diameter
Thickness of heat insulation
Material of heat insulation
Table 5
2.4

Information on refrigerant

This device contains fluorinated greenhouse gases as refrigerant.
The device is hermetically sealed. You will find the information on the
refrigerant according to the Regulation (EU) No 517/2014 on
fluorinated greenhouse gases in the operating instructions of the device.
Information for the installer: If you refill refrigerant, enter the additional
charge size and the total charge size of the refrigerant in the table
"information on refrigerant" of the operating instructions.
Climate 3000i – 6721823680 (2022/11)
Alternative pipe diameter [mm]
6
10
12
16
3 m
5 m
With Ø 6.35 mm (1/4"):
12 g/m
With Ø 9.53 mm (3/8"):
24 g/m
≥ 0.8 mm
≥ 1.0 mm
≥ 6 mm
Polyethylene foam

Publicité