Technical Specifications - Rocal D-8 Manuel Des Caracteristiques, Installation Et Fonctionnement

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1. SPECIFICATIONS

1.1 Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O2
NOx concentration at 13% of O
OGC concentration at 13% of O
Particle concentration at 13% of O
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Base safety distance
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body
2. Flue liner connector
3. Ceiling plate
4. Tool for handling registers and opening door
5. Upper baffle to limit the draught
6. Aluminium ring to connect, metal clamp, exterior air inlet cover and fixative of the aluminium ring
7. Heat-resistant glove
8. Cleaning cloth
9. Envelope with documents: declaration of performance, energy label, specifications, installation and operation manual, and
Guarantee sheet.
10. Heat-resistant spray paint for touch-ups
11. Bag with metallic anchors, anchors and screws.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Wall. Make sure the wall where the appliance will be placed is able to support the weight of the device. If not, you will need a load
spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2
2
2
Value
11-13 Pa
2 kg/h
5,99 g/s
87 %
11,3 kW
7,5 - 13 kW
0.08 %
97,52 mg/Nm
69,90 mg/Nm
29,72 mg/Nm
11,2 Pa
180 kg
4 kg
200 mm
450 mm
4000 mm
200 mm
100 mm
1000 mm
500 mm
400 mm
300 mm
150º C
INTERMITTENT
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
2018
18-18684/2312
3
3
3
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

X1285v6