The property owner has the following responsibilities:
a.
To maintain the area around the boiler clean at all times and
free from combustible and highly flammable material;
b.
The ambient air around the boiler must not be excessively
dusty or humid;
c.
To have all water leaks repaired in the system as they arise.
CAUTION
The boiler guaranty may be invalidated if: water
leaks in the system are not repaired; the boiler is
used as a source of domestic hot water or a
significant amount of new water or air is
introduced into the system.
It is recommended that the boiler be purged annually, in order to
eliminate sediment and sludge, which may have accumulated at the
bottom of the boiler and covered the heating elements.
Model:
Installation date of the electric boiler:
Service telephone # – Day:
Dealer name and address:
6
SECTION 3
MAINTENANCE
Procedure:
1.
Let the boiler cool down;
2.
Close the maintenance valves, which are installed at the water
inlet and outlet of the boiler. N.B.: It is not recommended to
drain the water from the heating pipe system;
3.
Hook-up a garden hose to the drain valve and place it close to
a floor drain;
4.
Open the purge valve until the water comes out clean and
clear;
5.
Close the valve.
It is recommended to perform a visual inspection of the boiler
electrical compartment annually, during the heating season. The
items to check are the water tightness of the elements, signs of
overheating of the electrical components and the wiring. Corrective
measures must be undertaken as required, as soon as possible.
Defective components should always be replaced with the Original
Equipment Manufacturer's parts.