Optional Temperature Limiting Adjustment - Kohler K-18486 Mode D'emploi

Masquer les pouces Voir aussi pour K-18486:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Handle
Bonnet

Optional Temperature Limiting Adjustment

NOTE: The water temperature does not need to be adjusted if the
water temperature is below 105°F (41°C).
NOTE: Before adjusting the water temperature, ensure the handle is
turned all the way to the left. This is the maximum hot position.
Remove the plug button, setscrew, handle, and bonnet.
Reposition the indexer to stop the valve stem at the desired
maximum temperature.
Allow the water to flow through the spout and rotate the valve
stem to the full hot position.
Using a thermometer, confirm the temperature setting.
Repeat the above procedures until the desired temperature is
reached.
Reinstall the bonnet, handle, setscrew, and plug button.
Lifetime Limited Warranty
Kohler Co. warrants its faucets manufactured after January 1, 1997, to
be leak and drip free during normal residential use for as long as the
original consumer purchaser owns his/her home. *If the faucet should
leak or drip during normal use, Kohler will, free of charge, mail to the
purchaser the cartridge necessary to put the faucet in good working
condition.
Kohler Co.
All manuals and user guides at all-guides.com
Setscrew
Plug Button
Valve
Stem
Indexer
3
1056154-5-C

Publicité

Table des Matières
loading

Table des Matières