Unearthed PV array
+/-
-/+
Earhed PV array
+
-
PE Schutzleiter / Protective Earth
SPD Conductor min. cross section
z , PE
SPD Earthing Conductor
+/-, -/+
SPD Live Conductor
2.13 [54]
inches
[mm]
max. 2.7 [70]
Product name:
U
(+)-PE, (-)-PE, (+)-(-)
CPV
+/-
-/+
V
(+)-PE, (-)-PE, (+)-(-)
PVDC
I
(8/20)
n
I
(8/20)
Total
I
(8/20)
max
U
(+)-PE, (-)-PE, (+)-(-)
p
VPR
(+)-PE, (-)-PE, (+)-(-)
I
SCPV
MET
I
CPV
SCCR (UL 1449)
I
(per UL 1449)
q
I
(AC / DC)
PE
SPD Failure Mode
+
Type of PV systems
-
Ta
RH
Mounting
Number of ports / IP
Location
Altitude (max)
MET
Terminals:
(solid, stranded) 18 mm
(flexible) 18 mm
RC push in (solid)
Minimum distance from any conductive surface [altitude up to 2000 m]
ø min 6 mm
2
Minimum distance from any conductive surface [altitude from 2001 m to 4000 m]
ø min 2.5 mm
2
PH2 / SLOT ¼
4.5Nm [40 lnf∙in]
Green / Grün
Vert / Verde
Red / Rot / Rouge
Rojo / Rosso
Replace Plug
Stecker ersetzen
Remplacez la prise
Sustituya la conexión
Sostituire la cartuccia
Green / Grün
Vert / Verde
SG2 DG K10M3
SG2 DG K10M3R
1100 V
1100 V
20 kA
50 kA
40 kA
3800 V
2500 V
11 kA
<20 µA
50 kA
<100 µA
< 0.5 mA / <20 µA
Open Circuit Failure Mode (OCFM)
Not earthed / earthed
-40 ºC to +85 ºC [-40 ºF to +185 ºF]
5 %...95 %
35mm DIN rail, EN 60715
1 / 20 (built-in)
Indoor
4000 m [13123 ft]
ø min 1.5 mm
2
/ ø max 35 mm
2
[ø min 15 AWG / ø max 2 AWG]
ø min 1.5 mm
2
/ ø max 25 mm
2
[ø min 15 AWG / ø max 4 AWG]
10 mm
ø min 0.25 mm
2
/ ø max 1.5 mm
2
[ø min 23 AWG / ø max 16 AWG]
OFF
ON
ON
OFF
Red / Rot / Rouge
Unplugged / Nicht eingesteckt
Rojo / Rosso
Débranché / Desconectado / Scollegato
SG2 DG K50M3
Step 1: Unlock / Schritt 1: Entsperren /
Étape 1: Déverrouillage / Paso 1: Desbloquear /
SG2 DG K50M3R
Fase 1: Sbloccare
1500 V
1500 V
20 kA
40 kA
30 kA
5000 V
4000 V
11 kA
<50 µA
65 kA
<100 µA
< 0.5 mA / <50 µA
Open Circuit Failure Mode (OCFM)
Step 2: Pull module out / Schritt 2: Modul herausziehen /
Not earthed / earthed
Étape 2: Extrayez le module / Paso 2: Sacar el módulo /
Fase 2: Tirare fuori la cartuccia
0 mm
0 mm [1100 V]
2 mm [1500 V]
RC contact(s) states /
Fernmeldekontakt(e)-Status
SPD module(s) functional /
installation is protected
SPD-Modul(e) funktional /
Installation ist geschützt
SPD module(s) unplugged or
non-functional / installation is unprotected
SPD-Modul(e) nicht eingesteckt oder
nicht funktional / Installation ist ungeschützt
A.C.
ON
OFF
D.C.
11- 12
11-14
Closed
Open
Geschlossen
Offen
Open
Closed
Offen
Geschlossen
250V / 1A
125V / 1A
48V / 0.5A
24V / 0.5A
12V / 0.5A