REMOVING THE OLD REGULATOR
NOTE: If you are converting your appliance from an existing regulator as seen below, it must be
removed before you can use the new regulator/hose assembly in this kit. If your existing regulator
was for a Natural Gas (NG) appliance, you will also need a Gas Conversion Kit to change all your
EN
orifices from NG to LP. Please contact your Hestan dealer to order the appropriate kit.
HESTAN POWER BURNER
(MODEL AGPB24-LP shown)
REMOVE THIS
REGULATOR
INCOMING
1/2" ID FLEX HOSE,
LP GAS SUPPLY
ELBOW & NIPPLE
(SUPPLIED BY
CUSTOMER)
SHUTOFF VALVE
(SUPPLIED BY
CUSTOMER)

GAS CONNECTIONS

GAS SUPPLY
Gas connections should be made by a qualified plumber, or your professional outdoor appliance
installer.
Make certain new piping and connections have been made in a clean manner and have been purged
so that piping compound, chips, etc. will not clog regulators, valves, orifices, or burners. Use pipe
joint compound / thread sealant approved for natural and LP gases.
NEVER CONNECT THE APPLIANCE TO AN UNREGULATED GAS SUPPLY. Before proceeding,
ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an improper gas type
will result in poor performance and increased risk of damage or injury. Gas type and gas consumption
(BTU per hour) for each burner type is shown on the rating label affixed to the underside of the drip
tray.
Installation of this cooking appliance must be made in accordance with local codes. In the absence of
local codes, this unit should be installed in accordance with the National Fuel Gas Code No. Z223.1/
NFPA 54 , Natural Gas and Propane Installation code CSA B149-1, or Propane Storage and Handling
Code B149.2.
NOTE: See rating label for manifold pressure for the type of gas of your appliance. To ensure proper
heating performance of this appliance, verify that the supply pressure is adequate (11.0" WC supply
pressure is preferred) to maintain 10.0" WC manifold pressure.