chosen location. Mark the ceiling for cutout by using the
heater housing' s flange as a template. Make the cutout.
5. Install the housing in the opening using hanger bars or
mounting tabs as described above.
6. Remove the desired electrical knockout from the junction box
in the housing.
Electrical Wiring
CAUTION: Make sure the power is switched off before
making this installation.
NOTE: All wiring must comply with local and national codes.
You must ground this unit.
NOTE: This unit must be wired on a separate 20 amp circuit.
You will have to get the heater' s wire compartment cover from
the carton.
1. Run 4 wires and a ground (12GA) from the heater box to
the wall box (location of the switches). Make sure you
identify which wire is for which component. The following is
the colour code in the heater' s junction box: Black wire =
Night Light, Yellow wire = Light, Red wire = Heater, White
wire = Neutral. Connect the ground wire to the green
ground screw in the heater' s junction box.
2. Make sure you connect the ground in the outlet box as
well.
3. Replace the junction box cover in the heater housing when
the wiring is complete.
Completing the Installation
You will need to get the grill, lens and light reflector from the
carton.
1. Once you have mounted the housing and completed the
wiring you can install the light reflector and the grill and
lens. First plug in the fan and heater into the heater' s wire
compartment cover.
2. Install the light reflector in the centre of the heater housing
and secure it with the screw removed earlier. Plug the light
and night light into the heater' s wiring compartment cover.
Install a 100 watt max. bulb (26 watt max. fluorescent for
model AK965FL) and a 7 watt max. night light bulb.
3. The heater' s lens flips down, release the lens by pushing on
the 2 tabs which hold it in place in the grill.
4. Secure the grill and lens to the heater housing via 2 screws
(provided). Flip the lens back into position.
AIR KING LIMITED, 110 GLIDDEN ROAD, BRAMPTON, ONTARIO, CANADA; TEL. 905-456-2033, 1-800-465-7300, FAX. 905-456-1015
(Refer to Fig. 2)
INSTALLATION
INSTRUCTIONS
AK960 WIRING DIAGRAM
HEATER
ELECTRICAL BOX
HOUSE
ELECTRICAL BOX
GROUND
LIGHT
HEATER
GROUND
NIGHT
LIGHT
TRIPLE
SWITCH
120V 60HZ
Fig 2.