MAINTENANCE/UV LAMP INDICATOR

Your Air Scrubber Advanced by Aerus unit requires no periodic maintenance
beyond normal replacement of the ActivePure® Cell every 2 years . UV bulb has
an effective life of 18,000 continuous hours .
The UV lamp operation indicator on the face of the unit will glow when the
UV lamp is in use . If the indicator does not glow and the unit has power, the
ActivePure® Cell should be replaced .
CHANGING THE ACTIVEPURE® CELL
CAUTION: Disconnect power at the breaker or fuse panel before servicing unit . Always follow OSHA
WARNING: UV Light in operation . Disconnect unit from power cord before servicing . Failure to
1 . Disconnect (unplug) power cord from unit .
NOTE:
Always follow OHSA electrical
lockout safety requirements
to prevent Accidental release
of energy during service or
maintenance activities .
4. Remove the 2 thumb screws
holding the ActivePure
7 . Secure with 2
thumb screws .
8
All manuals and user guides at all-guides.com
lockout procedures to prevent accidental exposure to electrical energy .
follow warnings may result in severe eye damage .
Power
Cord
5 . Separate the used ActivePure® Cell
Cell.
®
8. Insert the unit into
the mounting plate.
2. Remove the 4 thumb nuts.
from the base unit and dispose of
properly .
UV Lamp Operation Indicator
AIR SCRUBBER ADVANCED
UV LAMP in operation when lit.
AIR & SURFACE PURIFICATION
HVAC ENVIRONMENTAL CONDITIONING SYSTEM
3 . Remove the unit from the
mounting plate .
6. Plug the new ActivePure
Cell into the base unit. Be
sure Air Flow / Honeycomb
Cell direction is correct.
9 . Secure unit
with 4 thumb nuts .
®
10. Reconnect
power cord.