Télécharger Imprimer la page

Vimar ELVOX 6344 Manuel Installateur page 3

Publicité

6344 - 6354
The instruction manual is downloadable from the site www.vimar.com
DESCRIPTION
Monitor for video door entry system with 4 and 8 digit coding and decoding. Provided with
fixing bracket with terminal block, 3 push-buttons (lock release and 2 adidtional functions),
3 level call volume adjustment and exclusion of call signalled by red led. The green LED is
used for an additional signaalling (when properly connected).
This monitor is used in conjuction with power supply type 6948.
204 mm
Monitor technical specifications
- Wall-mounted monitor in ABS
- Backing plate and plugs for wall-mounted fixture or 3-module box.
- TFT LCD 3,5" for 6344 and 6354.
- Electronic circuit on interchangeable cards.
- Standard video signal CCIR 625 lines 50 squares for 6344 (b/w) and PAL for 6354
(color).
- Video pass band 4 MHz
- Operating temperature from 0° to +40° C.
- Electronic ringtone.
- Input for door calls with different ringtone from panel calls.
- Output for additional ringtone.
PROGRAMMING AND OPERATION
To program the monitor number press (by inserting a small screwdriver through the hole
Fig. 1, detail A) the push-button
and keep pressed the push-button. If the operation has been carried out correctly, the set
enter the programming mode by lighting the diode LED (Fig. 1, detail B) also visible through
the hole under the monitor. Now the push-button
not light up repeat the operation. Lifting the monitor handset it is possible to communicate
with the secondary entrance panel in order to send the code related to the monitor to be
programmed. When the code coming from the entrance panel arrives to the monitor, this
stores it and keeps it in memory until the next programming, even during a mains failure.
The monitor will switch the led off confirming the programming. During the programming
phase the lock release command is not active. In case of installations with stairs with more
than one entry, for the only programming phase , it is necessary to remove the connector
related to the monitor riser of entrance panels, leaving only one in function. The program-
ming operation may be repeated several times by using numbers included between
00000001 and 99999999.
PROCEDURE FOR "TOUCH KEY" PROGRAMMING
To program a "touch key" in the monitor memory follow the underwritten procedure:
1) Call the monitor from a digital keypad entrance panel
2) Re-dial the number and press the intercommunicating call push-button from the en-
trance panel
3) Select the position in the memory, by using the "FRECCIA SU" (arrow up) and "FREC-
CIA GIU'" (arrow down), where you want to memorize the key and press C.
4) Lean the key "TOUCH" in the proper entrance panel slot; you will hear an acoustic
signal on the monitor handset.
5) From now you will have 5 seconds to memorize the key by pressing the monitor "lock"
push-button; once the programming has been carried out you will hear three beeps
and the monitor will switch off. If the programming time expires before you press the
lock push-button, the interphone will switch off without programming the key and all the
procedure must be repeated from the beginning.
ADJUSTMENT OF CALL/UNATTENDED CALL FUNCTION
The 4 position selector (Fig. 1, detail C) allows the loudspeaker volume to be ajusted and,
if set to the last left position, it excludes the audio by lighting the red LED. If a call is made
during this period, the monitor does not sound and it is not activated, but it signals the call
making the led flash and a call be routed to the switchboard. The number of flashings (max
4) indicates the number of incoming calls. Setting the selector again, the normal operation
is re-establised and the number of incoming calls stored in the memory on this mode is
cancelled.
VIDEO SIGNAL CONNECTION
If the video signal is connected by a coaxial cable, the deviator (Fig. 2, detail A) (placed on
74 mm
present on the lower side of monitor and then press
can be released. If the diode does
*
.
the monitor rear side) must be set to the left hand position for the coxial cable version, or in
the right hand position for version withoutcoaxial cable.
N.B. The jumper present on the monitor rear side allows the VIDEOMOVING function
to be carried out on preset entrance panels or Function 2; on the contrary with cut
jumper it allows the selfactivation function to be carried out (Fig. 2, detail B), see
entrance panel programming.
TERMINAL BLOCK
1)
Digital call line
2)
Secondary entrance panel audio line
3)
Audio line
4)
Negative line
5)
+ 13,5V DC line
6)
Inserted monitor signalling (for additional chimes or other services)
7)
Monitor negative line
8)
Monitor positive line
9)
Line for outside door call.
10) Supply voltage for video floor distributor
11) F2 - connection for auxiliary functions, to be connected if indicated on the diagram.
12) F1 - Connection for auxiliary functions, to be connected if indicated on the diagram.
13) Supply voltage for green LED indicator
Lower side of monitor
Fig. 1
Rear monitor
Installation rules
Installation should be carried out by qualified personnel in compliance with the current
regulations regarding the installation of electrical equipment in the country where the products
are installed.
Conformity
EMC directive
Standards EN 61000-6-1 and EN 61000-6-3.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means
the product must not be included with other general waste at the end of its working
life. The user must take the worn product to a sorted waste center, or return it to the
retailer when purchasing a new one. Products for disposal can be consigned free of charge
(without any new purchase obligation) to retailers with a sales area of at least 400m
measure less than 25cm. An efficient sorted waste collection for the environmentally friendly
disposal of the used device, or its subsequent recycling, helps avoid the potential negative
effects on the environment and people's health, and encourages the re-use and/or recycling
of the construction materials.
EN
Fig. 2
6354
Videocitofono
Giotto colori Digibus
18V
INT 6,2W
CON PONTICELLO INSERITO = FUNZIONE F2
PONTICELLO TAGLIATO = FUNZIONE AUTOACCENSIONE
WITH JUMPER INSERTED = FUNCTION F2
WITH JUMPER CUT = SELFACTIVATION FUNCTION
Vimar SpA Viale Vicenza 14
36063 Marostica VI Italy www.vimar.com
, if they
2
3

Publicité

loading

Ce manuel est également adapté pour:

Elvox 6354