PEAK HOLD MODE OPERATION
Note:
1. If
appears, it means the wrench has been torqued to more than 110% of
maximum torque.
2. If
appears, it means the wrench's memory is full and no more values can be
recorded. Please refer to the "Peak Hold Mode Recorded Value Review" section to clear
the momory records.
3. When 80% of the target torque is reached, the green LED will begin to flash and the alarm
tone will beep intermittently.
4. When 99.5% of the target torque has been reached, the alarm will change to a steady tone
and the green LED will stop flashing and stay on. The red LED will also illuminate.
START
(System initiate)
*Nota 1
Setting Target Torque
Released
Apply Torque
Current Torque Value
(Peak Hold)
Buzzer
Buzzer
*Nota 2
Record saved and
transmitting wirelessly
Green LED
Reached 80% of Target Torque
Red LED
Approaching Target Torque
37