PRODUCT INSTALLATION

Do not install the Filter Head Connection Asssembly further than 12 feet away from
either the water supply valve, or the Indicator Faucet.
Avoid unnecessary slack in the supply hoses when connecting to the water supply, Filter
Head Connection Assembly, or Indicator Faucet.
Do not install in direct sunlight, or a place where it will be directly exposed to freezing
temperatures.
STEP 1: T-VALVE INSTALLATION
Be sure to install the T-Valve on the cold water supply line. Running hot water through
the Coral Water Filtration System will damage the filters.
1. Close the cold water supply valve. Place a bucket, or similar
item, underneath the valve to catch any water that may spill
out during installation.
2. Unscrew the hose that connects the cold water supply valve
to the existing tap water faucet.
3. Ensure the rubber washer is inside the T-Valve, and then
screw the T-Valve Adapter onto the cold water supply valve.
NOTE: If the water supply valve is larger than the 3/8"
connection on the T-Valve, use the included 1/2" Valve
Adapters with Rubber Washers to connect the T-Valve and
the water supply hose.
4. Screw the cold water supply hose to the top of the T-Valve.
Be sure to keep the water supply valve closed.