Electrical Requirements - Kitchen KOCE500EBS Manuel Du Propriétaire

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The front face of the cleats and platform will be visible and should
be treated as a finished surface.
Front View
27" (68.6 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 27
1
/
" (69.2 cm) minimum
4
width of flush inset cutout
C. 25
7
/
" (65.7 cm) minimum
8
width of opening
D. 43
1
/
" (109.5 cm) minimum
2
height of flush inset cutout
E. 42
1
/
" (107.9 cm)
2
recommended cutout height
F.
11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I.
4
5
/
" — 19
1
/
" (11.7 - 48.9 cm)
8
4
bottom of cutout to floor
J.
25" (63.5 cm) minimum depth
of cutout
* Cleats and spacers must be recessed 1
front of the cabinet.
Side View
30" (76.2 cm) models
A. 5/8" (1.6 cm) top cleat*
B. 30
1
/
" (76.8 cm) minimum
4
width of flush inset cutout
C. 28
7
/
" (73.3 cm) minimum
8
width of opening
D. 43
1
/
" (109.5 cm) minimum
8
height of flush inset cutout
E. 42
1
/
" (107.9 cm)
2
recommended cutout height
F.
11/16" (1.7 cm) side cleat*
G. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
H. Recommended junction box
location
I.
4
5
/
" — 19
1
/
" (11.7 - 48.9 cm)
8
4
bottom of cutout to floor
J.
25" (63.5 cm) minimum depth
of cutout
3
/
" (3.5 cm) from the
8
27" (68.6 cm) models
A. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
1
/
" (3.5 cm) recess from front
2
of cabinet
D. 11/16" (1.7 cm) side cleat*
* Cleats and spacers must be recessed 1
front of the cabinet.

Electrical Requirements

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and the wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA
70-latest edition or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. O-M91-latest edition, and all local
codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Top View
30" (76.2 cm) models
A. 1/2" x 2" (1.3 cm x 5.1 cm)
spacer the entire depth of the
cutout*
B. 25" (63.5 cm) depth of cutout
C. 1
1
/
" (3.5 cm) recess from front
2
of cabinet
D. 11/16" (1.7 cm) side cleat*
3
/
" (3.5 cm) from the
8
9