Viking G6MD Manuel D'instructions page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LOCATION OF PROBE AND PRESSURE SWITCH
The probe must be mounted between the range hood damper
and the wall cap, roof cap, in-line blower or external blower.
make sure the hood damper operation is not affected.
IN-LINE
DAMPER
HOOD
FLUE
TYPICAL INSTALLATION WITH
INTERNAL BLOWER AND ROOF VENT
IN-LINE
DAMPER
HOOD
FLUE
TYPICAL INSTALLATION WITH
INTERNAL BLOWER AND WALL VENT
KITCHEN
CABINET
PRESSURE
SWITCH
TYPICAL INSTALLATION WITH
INTERNAL BLOWER AND HORIZONTAL
DUCTING w/ WALL VENT
ROOF CAP
w/DAMPER
EXHAUST
DUCT
PRESSURE
SWITCH
PROBE
RANGE
HOOD
WALL CAP
w/DAMPER
EXHAUST
DUCT
PRESSURE
SWITCH
PROBE
RANGE
HOOD
TUBING
PROBE
WALL CAP
w/DAMPER
RANGE
HOOD
MODELS G6MD • G8MD • G10MD
The pressure switch should be mounted so it is accessible for
any future service. The switch can mounted no more then 72"
away from the probe. If longer tubing is required then what is
supplied, purchase 1/4" I.D. PVC tubing from a local source. See
the illustrations below for possible installation scenarios.
INLINE
BLOWER
HOOD
FLUE
TYPICAL INSTALLATION WITH INLINE BLOWER
HOOD
FLUE
TYPICAL INSTALLATION
WITH EXTERIOR BLOWER
Page 5
ROOF CAP
w/DAMPER
EXHAUST
DUCT
PRESSURE
SWITCH
PROBE
RANGE
HOOD
EXTERIOR
BLOWER
EXHAUST
DUCT
PRESSURE
SWITCH
PROBE
RANGE
HOOD

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

G8mdG10md

Table des Matières