NC-1W WALL HUNG CONDENSATE NEUTRALIZATION KIT
INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
Installation Instructions
NOTE - Check with your local water authority for regulations regarding discharge of treated condensate to the drain or
sewer system.
WARNING
-
"Risk of damage to appliance". The neutralization kit inlet and discharge must be at a lower elevation than the
condensate drain from appliance.
-
Do not allow exhaust flue gases to vent through the neutralization kit. All condensate drains must have a trap to
prevent flue gas leakage. Flue gas leakage can cause injury or death from carbon monoxide.
-
Connection to the appliance and neutralization kit must be installed to ensure that no condensate backflow into
the appliance can occur.
-
This product can expose you to Silica, crystalline (airborne particles of respirable size) which is known in the
state of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Open the capsule and ensure media is level inside. If necessary, the orientation of the NC-1W can be reversed by removing
the wall bracket and moving it to the other side of the lid. (see figure 1 below). Mount the neutralization capsule on the wall
securing it with the provided wall bracket (see figure 2 and 3 below).
Reversible
Figure 1
Connections to the appliance and neutralization kit must be installed to ensure that no condensate backflow can occur.
Connect corrosion resistant piping and secure it to the wall to prevent movement. Do not route the condensate line through
any area that is exposed to freezing temperatures or sunlight. If traffic poses a risk, install some protection to prevent
movement and/or damage. Mount as per installation diagram. The NC-1W should be installed after the trap. Ensure that the
condensate will flow freely from the appliance drain into the capsule then to the drain. Access to the discharge is necessary for
proper maintenance in order to check the effectiveness of the neutralizing media, using pH test strips.
If there is no gravity drain available, install a condensate removal pump designed for use on condensing boilers and furnaces.
The condensate pump must be equipped with an over flow switch to prevent the appliance from running should a failure
occur.
Operation
The appliance condensate will flow through the neutralizing media, raising the pH of the condensate to a level that
will help prevent corrosion of the domestic drain and the public sewer system.
3603 Burron Avenue, Saskatoon, SK S7P 0 Ph: (306) 651-1815 email: sales@axiomind.com
website: www.axiomind.com
Wall bracket
Figure 2
Provisionally Patented
Condensing
© 2019 Axiom Industries Ltd.
Wall Hung
Boiler or
Furnace
Clearance: 70mm [3.75"]
Figure 3