RJG 9204 Manuel Du Produit page 19

Capteur de pression à cavité piézoélectrique simple/ multicanal de 12,6 mm
Table des Matières

Publicité

Drawing Title: 9204-03
SPÉCIFICATIONS D'INSTALLATION (suite)
INSTALLATION DANS LA PLAQUE DE SERRAGE
**CLAMP PLATE INSTALLATIONS FOR PIN ≤ Ø0.25 [7.0]; PINS > Ø0.25 [7.0] USE HEAD-TO-HEAD INSTALLATION ON SHEET 9204-04 & -05.**
B
C
NOTES:
1.
CLAMP PLATE APPLICATIONS REQUIRE GUIDED EJECTION
2.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN 0.030" [0.76] OR
10% OF EJECTOR PIN DIA, WHICHEVER IS SMALLER.
3.
ENCLOSED EJECTOR BOX SUGGESTED.
4.
DO NOT SCALE PRINT
5.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
6.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
7.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
Manuel du Produit | Capteur de Pression à Cavité Piézoélectrique Simple/Multicanal de 12,6 mm 9204
Single-Channel Piezoelectric 12.6 mm Sensor (9204) Installation—Clamp Plate Installation
B-Plate or Cavity Insert
Ejector Pin Installed with
Normal Slip-Fit Tolerances
H7/g6
Ejector Retainer Plate
Ejector Plate
Lead-In Chamfer
Ejector Pin Shoulder Ø and Transfer Pin Ø Equal
0.5 MIN [12 MIN]
Fit Must be 1/3 of Pin LEgnth, Else
**Consider Head-to-Head Installation**
Clamp Plate
Cover Plate 32HRC
REFER TO TABLE E
Pin Ø
3/32–7/64" [2.5–3.0]
9/64"–5/8" [14.0–23.0]
0.020 MIN
0.5 MIN
Per Side
45°
REFER TO TABLE D
If Pin Ø < 0.12 [3.0], Ø + 0.04 [1.0]
If Pin Ø > 0.12 [3.0], + 0.06 [1.5]
0.001 [0.03] F
0.001 [0.03]
TABLE E
MIN Plate Thickness
0.2 [5]
0.25 [6.0]
Part Thickness < 0.05 [1.5], 1/5 of Thickness
Part Thickness > 0.05 [1.5], 0.01 [0.3]
0.04–0.08 [1.0–2.0]
0.10–0.20 [2.5–5.0]
0.24–0.40 [6.0–10.0]
0.01 MIN
0.3 MIN
Counterbore in Ejector Plate
Transfer Pin Flush with Ejector Plate
Counterbore Ø = Pin Head Ø + 0.04 [1.0] MIN
DETAIL B
SCALE 2.5 : 1
F
0.004
0.504 + -
0.000
+ 0.1
12.8
0.0
DETAIL C
SCALE 2.5 : 1
TABLE D
Ejector Pin Ø
Chamfer Length
0.01 [0.3]
0.02 [0.4]
0.025 [0.6]
0.01
0.3
0.378 + -
0.004
0.000
+ 0.1
9.6
0.0
45°
REFER TO
TABLE D
Description: 9204 Sensor
Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 09.23.2021
RJG, Inc.
11

Publicité

Table des Matières
loading

Table des Matières