Application
The RC840T Electric Heating Relay is designed to control a line
voltage resistive load from a low voltage thermostat. The RC840T
relay has a built-in 24 V transformer and is compatible with 3-wire
(R,C,W) thermostats as well as 2-wire mechanical and battery-
operated thermostats.
The RC840T operates silently and can be installed in bedrooms,
living rooms, or any other occupied area without disturbing
occupants. On a call for heat, the relay is immediately activated;
there is no delay. This increases temperature control and comfort.
NOTE:
Not recommended for fast-cycling modulated regulation. For
fast-cycling heating equipment, It is recommended to use the RT850
or RT850T (integrated 24 V transformer) Solid State Relay.
I
Installation
The RC840T must be installed in an area where the temperature is
between -4°F and 140°F (-20°C and 60°C).
The RC840T can be installed on the side of an electrical box or a
distribution panel or inside the wiring compartment of an electric
baseboard.
On the side of
an electrical box
 All wiring must comply with national and local electrical
code regulations.
 Installation should be carried out by an electrician.
 Disconnect power supply before installing the relay to
prevent electrical shock.
Secure relay to the mounting surface using the two mounting
brackets. Use the supplied lock nut to secure the relay to the
junction box.
Wire the relay and connect according to typical wiring diagrams
(refer to figures 1 & 2).
RC840T
On/Off Switching Electric Heating Relay with Built-in 24 V Transformer
For proper installation, use
a screw and a washer.
Inside the wiring compartment
of a baseboard
1.
Once mounting and wiring have been completed, return power
to the heating system and test the installation.
Increase the thermostat temperature to activate the relay. Allow
system operation long enough to proof installation. Once
installation has been proofed, set temperature to normal
setpoint.
Typical Wiring Diagrams
2.
Low-voltage
2-wire
thermostat
You must provide an overload protection and
disconnect as required.
Figure 1 :
Connection to a 2-wire low voltage thermostat
Low-voltage
3-wire
thermostat
You must provide an overload protection and
disconnect as required.
Figure 2 :
Connection to a 3-wire low voltage thermostat
RC840T
Installation Guide
Load
Junction box
Red
Black
Blue/white
Load
Junction box
Red
Black
Blue/white
3.
1/2

Publicité

loading

Sommaire des Matières pour Aube Technologies RC840T

  • Page 1 The RC840T must be installed in an area where the temperature is thermostat between -4°F and 140°F (-20°C and 60°C). Black The RC840T can be installed on the side of an electrical box or a Blue/white distribution panel or inside the wiring compartment of an electric baseboard.
  • Page 2 RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces, states or regions do not allow the  RC840T Dimensions exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT.
  • Page 3 Connexion typique du relais et d’un thermostat bifilaire de se situe entre -20°C et 60°C (-4° et 140°F). basse tension Le RC840T peut être installé à l’extérieur d’une boîte de jonction, dans le compartiment de raccordement d’une plinthe électrique, ou à l’extérieur d’un panneau de distribution.
  • Page 4 VIOLATION QUELCONQUE D'UNE GARANTIE, EXPRESSE OU  TACITE, APPLICABLE AU PRÉSENT PRODUIT NI DE TOUTE Dimensions du RC840T AUTRE DÉFECTUOSITÉ DU PRÉSENT PRODUIT. Certaines provinces ou régions ne permettent pas l'exclusion ou la restriction des dommages indirects et, par conséquent, la présente restriction peut ne pas s'appliquer.