Télécharger Imprimer la page

Whale V- PUMP MK.6 Mode D'emploi

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Read carefully before
installation and use.
To the fitter: Check that
the product is suitable for the
intended application, follow
installation instructions and
ensure operating instructions
are passed onto the end user.
To the User: Read the
following instructions care-
fully.
Application
This product is designed for
use as a domestic freshwater
& saltwater hand pump in
caravans and boats. Use for
any other purpose or with
any other liquid, is not rec-
ommended and is entirely at
the user`s risk.
This pump may also be used
in conjunction with an in-line
pump, or as a back up to a
submersible pump.
Sub mer si bl e
921
All manuals and user guides at all-guides.com
V- PUMP MK.6
Installation
Choose an installation where
the pump can be operated
comfortably. Note: The
maximum reach of the outlet
spout is 115mm (4½")
Once you have found your
location, drill a 25mm (1")
hole, fit pump, position base
and secure using the two
wood screws.
Hose connection
If using Whale Water System
15 pipework WX1504 equal
straight will fit directly onto
the pump, if using
System12 use WX1504 &
WS1215 stem reducer 15mm-
12mm alternatively you can
use 13mm (½") flexible
tubing.
The height of the pump
maybe adjusted by loosening
screw (A).
Operation
To operate pump the handle
up and down, water will be
discharged on both strokes.
Maintenance
Regular inspection of valves
and seals is recommended
with cleaning and replace-
ment of components as
necessary.
To dismantle pump:
Unscrew head and spout from
Barrel, pull plunger and head
from barrel. Unscrew plunger
GP0650
Also Service Kits/Assemblies:
AK0618 & AS0627
cup seat from plunger rod and
pull head and spout from
plunger rod. To remove U-
Packing seal from head,
carefully ease cap (B) off using
a flat screw driver, replace U-
Packing seal making sure to fit
the new seal the same way
round as old seal (U facing
down).
Note: Replacing O-Ring (C)
may prove difficult to remove
and we recommend that it is
not replaced unless a leak is
observed under the head.
Replace cup washer, O-Ring
(D) and buffer on plunger cup
seat.
Reassemble making sure that
cap is securely pushed back
into position
To replace bottom valve (E)
unscrew base from barrel of
pump. A service kit AK0618
is available from dealers.
Contact Whale for MK5 V-
pump drawing or instruction.
NOTE: For winter storage,
ensure that the pump is
drained completely to avoid
frost damage.

Publicité

loading

Sommaire des Matières pour Whale V- PUMP MK.6

  • Page 1 Note: Replacing O-Ring (C) Hose connection may prove difficult to remove Application If using Whale Water System and we recommend that it is This product is designed for 15 pipework WX1504 equal not replaced unless a leak is use as a domestic freshwater straight will fit directly onto observed under the head.
  • Page 2 Cup packing* assemblies Buffer* Helpful Hints Warranty (a) If the pump is slow to This Whale product is cov- prime, the cup washer maybe ered by 1 years warranty. worn or the valves are not Please see the enclosed seating properly.
  • Page 3 Ainsi que les Kits d’entretien/Assemblages : AK0618 & AS0627 Raccord du flexible Lisez attentivement ce document avant Si vous utilisez un Système de distribution d’eau Whale d’installer et d’utiliser l’appareil. 15mm, le raccord droite WX1504 se fixera directement sur la pompe. Si vous utilisez le Système 12mm, utilisez A l’attention du monteur: Vérifiez que le produit est...
  • Page 4 - Vérifiez les rondelles dans la pompe, elles ont peut être besoin d'être remplacées. Garantie Les pompes Whale sont garanties 1 an pièces et main oeuvre. Si l’équipement se révèle défectueux, renvoyez-le à votre fournisseur avec la preuve et la date d’achat.

Ce manuel est également adapté pour:

Gp0650