Uline H-3768 Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAINTENANCE AND CHARGE OF BATTERY
1. A Rechargeable Gel battery is used in this lift table.
2. The H-3768 lift tables are equipped with a specific
charger to charge the battery. The charger can be
plugged into a standard 110 volt outlet.
CAUTION! Before connecting the charger to
the socket, make sure the emergency shutoff
switch and key switch are in the OFF position.
Please charge the battery in a dry, well-
ventilated area and away from any source
of fire. If the lift table is not in use, battery
charges should be performed no less than
once every six months.
3. The battery of the lift table should be charged
fully and regularly. When the battery reaches 20%,
please charge the battery immediately.
4. The charger will adjust the current according to
residual capacity of the battery automatically,
which ensures the battery is charged correctly.
After charging the battery, the charger indicates
full capacity and stops automatically. Charging
generally lasts 7-9 hours.
BATTERY INDICATOR
1.
BATTERY CAPACITY METER – The charge status of
battery is indicated on battery capacity meter. With
consumption of battery capacity, the gauge will
descend downwards from the top. (See Figure 3)
2. The lift table will automatically cut off lifting functions
when the battery reaches 20%.
Figure 3
Capacity Sufficient
V
30
20
10
0
PAGE 3 OF 12
MAINTENANCE
Charge Required
V
30
20
10
0
PREPARATION OF LIFT TABLE FOR REPAIR
OR MAINTENANCE
Take all necessary safety measures to avoid a possible
accident during the course of repair and maintenance:
1.
Park the lift table safely.
2. Press emergency shutoff switch and disconnect
the battery.
3. Apply the brake.
4. Lower the safety stand bar.
INSPECTION OF HYDRAULIC OIL CAPACITY
1.
Make sure the table is in the fully lowered position.
2. Remove the four screws (1). (See Figure 4)
3. Open the cover (2). (See Figure 4)
4. Check the capacity of hydraulic oil in oil tank.
INSPECTION OF ELECTRIC FUSE
1.
Remove the four screws (1). (See Figure 4)
2. Open the cover (2). (See Figure 4)
3. Check if the fuse is intact. Replace if necessary.
Figure 4
USING THE LIFT TABLE AFTER MAINTENANCE
Finish the following operation before use of lift table:
1. Clean the lift table.
2. Check the brakes.
3. Check the emergency shutoff switch.
2
1
0321 IH-3768

Publicité

Table des Matières
loading

Table des Matières