Refer to the chart below for recommended copper wiring for conductors with a temperature rating of 75°C:
FlowCo
LavAdvantage
SPEX1812
SPEX1812T
SPEX2412
SPEX2412T
SPEX3012
SPEX3012T
SPEX3512
SPEX3512T
SPEX35
SPEX35T
SPEX48
SPEX48T
SPEX55
SPEX55T
SPEX65
SPEX65T
SPEX75
SPEX75T
SPEX95
SPEX95T
-
SPEX012240T
SPEX3208
SPEX3208T
SPEX4208
SPEX4208T
SPEX8208
SPEX8208T
SPEX3277
SPEX3277T
SPEX4277
SPEX4277T
SPEX60
SPEX60T
SPEX80
SPEX80T
SPEX90
SPEX90T
SPEX100
SPEX100T
Power cable entry to the heater should be made through one of
the knock-out holes located on the back plate or top/bottom
ends of the unit. Use the appropriate strain relief fitting.
The power leads are to be secured to the L1 and L2 or L and N
connectors on the terminal block or relay. The ground lead is to
be secured to the GND connector on the block or the green
ground wire with the provided wire nut.
FAILURE TO GROUND THE SYSTEM MAY RESULT IN SERIOUS INJURY, DEATH AND/OR PROPERTY
DAMAGE.
8
Voltage
AccuMix II
(VAC)
-
120
-
120
-
120
AM004120T
120
-
240
AM005240T
240
-
240
AM007240T
240
-
240
AM010240T
240
AM012240T
240
-
208
-
208
-
208
-
277
AM004277T
277
-
277
AM008277T
277
-
277
AM010277T
277
Manufacturer's National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Max power
Max current
(kW)
(A)
1.8
15
2.4
20
3
25
3.5
29
3.5
15
4.8
20
5.5
23
6.5
27
7.5
32
9.5
40
11.5
48
3
15
4.1
20
8.3
40
3
11
4.1
14.8
6
22
8
29
9
33
10
36
Information contained in this document is subject to change without notice.
Minimum wire size
(AWG) @75°C
14
14
12
10
14
14
12
10
10
8
8
14
14
8
14
14
12
10
10
8