DECLARATION OF A STANDARDS CONFORMITY

The producer confi rms that the devices agree with 2009/142/ES standards, rule nr. 22/1997 sb., nr. 258/2000
sb.. nr. 258/200 sb. and with relevant goverment orders. Instalation must be done with respect to valid
standards. Attention, the producer refuses any responsibility in case of direct or indirect damages which are
caused due to wrong instalation, incorrect intervention or modifi cation, insuffi cient maintenance, incorrect
use and also possibly caused by other reasons presented by items in sale conditions. This appliance is set
only for skilled use and must be operated by qualifi ed persons only. Parts set and secured by the producer or
accredited person must not be rebuilt by user.

TECHNICAL DATA

Label with technical data is placed on the back side of the device. Study the electrical diagram of connection
and all following information before instalation.
MODEL
BURNER
NOZZLE OF BURNER
1/100 MM (3,0 KW)
SP - 30 GL
NOZZLE OF BURNER
1/100 MM (3,6 KW)
6,6 kW
CONSUPTION
BURNER 3,0 KW
BURNER 3,6 KW
NOZZLE OF BURNER
1/100 MM (2x 3,0 KW)
SP - 60 GL
NOZZLE OF BURNER
1/100 MM (2x 3,6 KW)
13,2 kW
CONSUPTION
BURNER 2x 3,0 KW
BURNER 2x 3,6 KW
NOZZLE OF BURNER
1/100 MM (3x 3,0 KW)
SP - 90 GL
NOZZLE OF BURNER
1/100 MM (3x 3,6 KW)
19,5 kW
CONSUPTION
BURNER 3x 3,0 KW
BURNER 3x 3,6 KW
NOZZLE OF BURNER
1/100 MM (2x 3,0 KW)
NOZZLE OF BURNER
1/100 MM (3x 3,6 KW)
SP - 90/5 GL
16,8 kW
CONSUPTION
BURNER 3x 3,0 KW
BURNER 3x 3,6 KW
DEVICE INSTALATION
Instalation, setting, rebuilding for another gas type, putting into operation must be done by qualified person who
is competent for this and according to the valid standards. The device can be instalated in good ventilated room.
When it is possible place the device under the fumehood to suck off the products of combustion. Air needy to the
burning is 2m/3/h/kW ot the performance of the instaled device.
The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm from other
subjects must be kept.It is also necessary to prevent our product from contact with combustible materials. In this
case you must make corresponding changes to secure heat izolation of combustible parts (for example:place
between the device and combustible material azbestos plate).
12,8 kWh/kg
G 30/G 31
NOZZLE
PROPAN /
BUTAN
28 - 30 mbar
85
96
0,218 kg/h
0,262 kg/h
85
96
0,436 kg/h
0,524 kg/h
85
96
0,654 kg/h
0,786 kg/h
85
96
0,436 kg/h
0,786 kg/h
12,8 kWh/kg
12,8 kWh/kg
G 30/G 31
G 31
PROPAN /
PROPAN
BUTAN
37 mbar
50 mbar
85
75
96
80
0,218 kg/h
0,218 kg/h
0,262 kg/h
0,262 kg/h
85
75
96
80
0,436 kg/h
0,436 kg/h
0,524 kg/h
0,524 kg/h
85
75
96
80
0,654 kg/h
0,654 kg/h
0,786 kg/h
0,786 kg/h
85
75
96
80
0,436 kg/h
0,436 kg/h
0,786 kg/h
0,786 kg/h
3
9,45 kWh/m
3
FEEDING
G 20
TUBE
NATURAL GAS
GAS
20 mbar
130
G 1/2"
155
G 1/2"
0,286 m
/h
---
3
0,343 m
/h
3
130
G 1/2"
155
G 1/2"
0,572 m
/h
----
3
0,686 m
/h
3
130
G 1/2"
155
G 1/2"
0,858 m
/h
----
3
1,029 m
/h
3
130
G 1/2"
145
G 1/2"
0,572 m
/h
---
3
1,029 kg/h
---