Setting The Clock; Selecting The Operating Mode; Manual Mode; Automatic Mode - Honeywell Home Rpls730B Mode D'installation Et D'emploi

Interrupteur mural programmable
Table des Matières
Les langues disponibles

Les langues disponibles

RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
POWER-ON
1.
Pry the switch door open from the bottom
using a small screwdriver.
2.
Ensure the ON/OFF selector is set to ON.
3.
Reset the switch using a paper clip. 0:00 will
flash.
If the display is blank:
Ensure the ON/OFF selector is properly
engaged in the ON position. Push it to the right
using a small screwdriver.
At first power-up after the installation, the
screen of the switch may be blank or dim, or
become so when you turn the light on. However,
during that time, the switch is fully functional. Wait 2 minutes for the
switch's built-in battery to be sufficiently charged and the screen will
return to its normal contrast.

SETTING THE CLOCK

NOTE:
The switch displays the time in 24-hour format by default or follow-
ing a reset.
1.
To change to 12-hour format (or vice versa), proceed as follows:
Press one of the control buttons to ensure the MAN or AUTO
indicator is displayed.
Press the MIN and HOUR buttons simultaneously and briefly (0:00
display = 24-hour, 12:00 display = 12-hour).
2.
Set the time using the HOUR and MIN buttons. If you have selected
the 12-hour format, ensure that PM appears on the screen when an
afternoon time is displayed.
3.
Set the day using the DAY button.
4.
Press one of the control buttons or close the switch door to return to
normal operation.

SELECTING THE OPERATING MODE

The programmable switch has 2 operating modes: manual (MAN) and
automatic (AUTO). To switch mode, press the switch door for 3 seconds.

Manual mode

The programmable switch operates as a regular switch.
Briefly press the switch door to turn the lights On or Off.
The mode (MAN) and state (ON or OFF) are displayed.

Automatic mode

The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF) and
current program number are displayed. To temporarily
override the programmed schedule, briefly press the
switch door. The new state (ON or OFF) will flash to show
that this state is temporary. The override remains in effect
until you press the switch door again or until the beginning of the next
program.
69-2457EFS—03
2
Reset
Control (4)
On/Off selector
M38498
M38499
Table des Matières
loading

Ce manuel est également adapté pour:

Rpls731b

Table des Matières