5. Anomalies de fonctionnement

Identifiez votre problème dans la colonne «
CONSTAT
CAUSES
1.
2.
3.
REFOULEMENT À
L'ALLUMAGE
4.
5.
6.
VÉRIFIER LES CAUSES: 1 - 2 - 3 - 4 - 5 - 6
7.
LE FEU NE
DÉMARRE PAS
8.
9.
VÉRIFIER LES CAUSES: 3 - 4 - 5 - 7
10.
LE FEU EST
11.
DORMANT
12.
13.
VÉRIFIER LES CAUSES: 3 - 5
14.
LE FEU EST
15.
TROP VIF
16.
17.
VÉRIFIER LES CAUSES: 5 - 7 - 10 - 11 - 12 - 13
LA VITRE NOIRCIT
18.
19.
34
» et suivez l'ordre des causes possibles.
constat
POSITION DE LA CHICANE
CHEMINÉE FROIDE
CONDITIONS ATMOSPHÉRIQUES
LOCAL EN DÉPRESSION
CHICANE MAL RÉGLÉE
OBSTRUCTION DU CONDUIT
PASSAGE DES AMENÉES D'AIR DE COMBUSTION
TROP FAIBLE
COMBUSTIBLE D'ALLUMAGE INSUFFISANT
HUMIDITÉ EXCESSIVE DU COMBUSTIBLE D'ALLU-
MAGE
HUMIDITÉ EXCESSIVE DU COMBUSTIBLE
FAIBLE QUANTITÉ DE COMBUSTIBLE
MAUVAISE QUALITÉ DU COMBUSTIBLE
THERMOSTAT ENDOMMAGÉ
FORTE QUANTITÉ DE COMBUSTIBLE
MAUVAISE QUALITÉ DU COMBUSTIBLE
AMENÉE D'AIR PARASITE
FERMETURE DU THERMOSTAT ENTRAVÉE
PROPRETÉ DE LA VITRE AVANT MISE À FEU
ENTRÉE D'AIR PARASITE
REMÈDES
LA REMETTRE CORRECTEMENT
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC BEAUCOUP DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
PRATIQUER L'ALLUMAGE INVERSÉ, AVEC BEAUCOUP DE PETIT BOIS (VOIR CHAPITRE ALLUMAGE)
ATTENDRE DE MEILLEURES CONDITIONS
AUGMENTER L'APPORT D'AIR DANS LE LOCAL (OUVRIR PORTE, FENÊTRE ET/OU ÉTEINDRE TOUT SYSTÈME D'ASPIRATION)
VÉRIFIER LA POSITION
FAIRE UN TEST À OUVERTURE MAXIMALE
PRÉVENIR L'INSTALLATEUR
APPLIQUER LE REMÈDE CORRESPONDANT
OUVRIR COMPLÈTEMENT LE THERMOSTAT
VÉRIFIER L'AMENÉE D'AIR EXTÉRIEUR
AUGMENTER LA QUANTITÉ
LE CHANGER PAR UN COMBUSTIBLE PLUS SEC
APPLIQUER LE REMÈDE CORRESPONDANT
AJOUTER DU COMBUSTIBLE PLUS SEC
AUGMENTER AU MINIMUM À LA CHARGE NOMINALE
UTILISER DU BOIS FENDU SANS ÉCORCE DE SECTION ADÉQUATE ET CORRECTEMENT DISPOSÉ
REMPLACEMENT PAR L'INSTALLATEUR
APPLIQUER LE REMÈDE CORRESPONDANT
RESPECTER LA CHARGE NOMINALE
UTILISER DU BOIS FENDU SANS ÉCORCE DE SECTION ADÉQUATE ET CORRECTEMENT DISPOSÉ
VÉRIFIER LA FERMETURE ET L'ÉTANCHÉITÉ DE LA PORTE DU FOYER
REMPLACEMENT PAR L'INSTALLATEUR
APPLIQUER LE REMÈDE CORRESPONDANT
NETTOYER SOIGNEUSEMENT LA VITRE
VÉRIFIER L'ÉTANCHÉITÉ DE LA PORTE