  • Page 1 CTB ECOWATT PLUS CRHB-N ECOWATT PLUS CRVB-N ECOWATT PLUS...
  • Page 3: Table Des Matières

    ESPAÑOL ÍNDICE 1. GENERALIDADES ..................................4 2. NORMAS DE SEGURIDAD Y MARCADO “CE” ..........................4 3. NORMAS GENERALES .................................4 4. DESCRIPCIÓN ....................................4 4.1. Ubicaciones ...................................4 4.2. Conexionado eléctrico y detalle placa interna ........................5 5. FUNCIONAMIENTO SIN CONSOLA PROSYS ECOWATT ......................6 6. FUNCIONAMIENTO CON ACCESORIO CONSOLA PROSYS ECOWATT ..................6 6.1.
  • Page 4: Generalidades

    1. GENERALIDADES Le agradecemos la confi anza depositada en S&P mediante la compra de este producto, que ha sido fabricado según reglas técnicas de seguridad, conforme a las normas de la CE. Antes de instalar y poner en funcionamiento este producto, lea atentamente el presente libro de instrucciones pues contiene indicaciones importantes para su seguridad y la de los usuarios durante la instalación, uso y mantenimiento de este producto.
  • Page 5: Conexionado Eléctrico Y Detalle Placa Interna

    IMPORTANTE En la parte inferior de la caja de control se pueden observar dos tubos marcados como “V” y “P” procedentes del interior del extractor de tejado. De fábrica se sirven con el tubo marcado como “P” conectado juntamente con el “V” desconectado y obstruido por un tapón.
  • Page 6: Funcionamiento Sin Consola Prosys Ecowatt

    Salidas Descripción Alimentación placa interna pasando por el interruptor (cableado en fábrica) GND, N, (J2) RELÉ (J3) Conmuta con la activación de cualquier alarma (carga máxima 2A) 0V, +V (J7) Salida analógica 0-10V hacia motor TACOM (J8) Cuenta revoluciones motor A, B (J10) Conexión a red de comunicación.
  • Page 7 Esquema de conexión control múltiple Es posible conectar hasta 32 ventiladores entre ellos para crear una red que pueda ser ajustada y controlada con una sola consola PROSYS ECOWATT. IMPORTANTE Previamente al cableado de la red de co- municación, es necesario confi gurar de forma independiente todos los extracto- res de tejado ECOWATT PLUS, asignán- dole a cada uno de ellos un número de...
  • Page 8 Para realizar el cambio del número del ventilador se deberán seguir los pasos siguientes: 3” Pulsar simultáneamente durante 3” Introducir la contraseña de acceso específica del canal. ENTRAR PASSWORD: Por defecto: 1 1 1 CAMBIAR PASSWORD Es posible asignar una nueva contraseña al equipo (canal) Selección sobre que canal se quiere realizar la MENU CONFIG configuración...
  • Page 9 Presionar sobre “OK” SALIDA-MAX < 100% Presionar sobre “NO” PARAM.NIVEL 2? < PROGRAMAR C:1? Presionar sobre “SI” para guardar cambios < SI SI Programacion OK Apretar cualquier tecla para volver a la pantalla inicial > <Pulsar tecla • Apagar el equipo mediante el interruptor paro/marca posición “0” •...
  • Page 10: Descripción

    6.2. DESCRIPCIÓN La consola PROSYS ECOWATT se utiliza como complemento de visualización y control. Permite realizar las siguientes funcio- nes: • Visualizar los parámetros y las variables del equipo • Guardar confi guraciones • Visualizar confi guraciones • Confi gurar el equipo y modos de funcionamiento •...
  • Page 11: Parámetros Generales

    6.4. PARÁMETROS GENERALES Una vez realizado el conexionado, alimentar el sistema mediante el interruptor paro/marcha. Al conectar el equipo aparecerá la siguiente pantalla: L L anguage: Idioma: Langue: Sprache: E E NGLISH H CASTELLANO FRANCAISE DEUTSCH Una vez elegido el idioma, aparece una pantalla con la siguiente información: S S i:xxxPa a S S c:100Pa a Si: xxx...
  • Page 12: Confi Guración De Los Equipos A Través De La Consola

    6.6. CONFIGURACIÓN DE LOS EQUIPOS A TRAVÉS DE LA CONSOLA 6.6.1. Modifi cación consigna Pasos a seguir para modifi car la consigna del equipo partiendo de la pantalla inicial: Valor medido (las unidades dependerán del modo de funcionamiento) Consigna Velocidad ventilador en % (sobre velocidad máxima) C: 1 Núm.
  • Page 13: Funcionamiento Modo Pi Presion (Cop)

    En este momento nos encontramos en modo confi guración y ya es posible navegar por los parámetros del equipo, confi guran- do el modo de trabajo: Presionando sobre “SI”, se vuelve a cargar la PARAMETROS DEF? PARAMETROS DEF? configuración de fábrica FUNC.
  • Page 14 SALIDA-MAX Pulsar para modificar manualmente el parámetro de salida máxima a motor < 100% Acceso a configuración de parámetros avanzados PARAM.NIVEL 2? PARAM.NIVEL 2? < < SI SI Introducir la contraseña de acceso específica del canal. ENTRAR PASSWORD: Por defecto: 1 1 1 Es posible asignar una nueva contraseña al equipo (canal) CAMBIAR PASSWORD TIPO MOTOR...
  • Page 15 Pulsar para modificar manualmente el RANGO parámetro. El valor que aparece en pantalla corresponde < 400Pa a la escala del sensor interno preajustado en fábrica. Si se instala un sensor externo, introducir el rango de escala correspondiente. CONSIGNA CONSIGNA CONSIGNA <CONSOLA OK <IN1 0-10V OK <...
  • Page 16: Entrada Digital

    SP-2 CAUDAL Pulsar para modificar manualmente el parámetro. Este valor corresponde al % sobre la presión < de consigna estando el ventilador en posición noche. Para ello se puede conectar un reloj o interruptor libre de potencial en la entrada digital J11 ENTRADA DIGITAL ENTRADA DIGITAL <...
  • Page 17: Funcionamiento Modo Pi Caudal/Cav

    6.6.4. Funcionamiento modo PI CAUDAL/CAV Primeramente, antes de seleccionar el modo funcionamiento PI CAUDAL mediante la consola PROSYS ECOWATT, es necesa- rio realizar la correcta conexión de tubos de presión. Colocar los tubos marcados como “V” y “P” tal y como se representa a continuación.
  • Page 18 No modificar TIPO MOTOR < SENSOR SENSOR SENSOR <IN1 0-10V OK <IN1 4-20mA OK < INTERNO SENSOR SENSOR <IN2 4-20mA OK <IN2 0-10V OK Sensor: Tipo de sensor - INTERNO: Sonda diferencial de presión interna - IN1 0-10V: Sonda externa señal analógica 0-10V (terminal J5) - IN1 4-20mA: Sonda externa señal analógica 4-20mA (terminal J5) - IN2 0-10V: Sonda externa señal analógica 0-10V (terminal J6) - IN2 4-20mA: Sonda externa señal analógica 4-20mA (terminal J6)
  • Page 19 Pulsar para modificar manualmente el valor CONSIGNA CONSOLA de consigna. Éste apartado sólo aparece si en menú < 1300m3/h OK “ ” se ha seleccionado “ ”. CONSIGNA CONSOLA Pulsar para modificar manualmente el PARAMETROS parámetro. Se aconseja no modificar. <...
  • Page 20: Funcionamiento Modo Proporcional/Vav

    SALIDA PULSOS Pulsar para modificar manualmente el parámetro que permite visualizar la velocidad del motor < mediante la salida J8 (TACOM). Se aconseja no modificar. Guardar en memoria parámetros modificados PROGRAMAR C:1? < SI SI Apretar cualquier tecla para volver a la pantalla inicial Programacion OK >...
  • Page 21 Sensor IN1: - SIN SENSOR: Ningún sensor conectado a esta entrada - 0-10V/4-20mA %HR: Sensor humedad salida analógica 0-10V/4-20mA - 0-10V/4-20mA TEMP: Sensor temperatura salida analógica 0-10V/4-20mA - 0-10V/4-20mA CO2: Sensor CO2 salida analógica 0-10V/4-20mA Pulsar para modificar manualmente el IN1 RANGO fondo de escala del sensor utilizado <...
  • Page 22 Introducir la contraseña de acceso específica del canal. ENTRAR PASSWORD: Por defecto: 1 1 1 CAMBIAR PASSWORD Es posible asignar una nueva contraseña al equipo (canal) TIPO MOTOR No modificar < Pulsar para modificar manualmente el S1-ALARMA parámetro. Este valor permite enviar un mensaje de <...
  • Page 23: Funcionamiento Modo Min/Max

    PROGRAMAR C:1? Validación parámetros modificados < SI SI Programacion OK Validación volcado programación > <Pulsar tecla 6.6.6. Funcionamiento modo MIN/MAX En este modo, la caja de control está preparada para trabajar mediante contacto, tipo normalmente abierto (NO) o normal- mente cerrado (NC), situados en la entrada digital J11. Cuando el estado de esta entrada cambia, el ventilador pasa a velocidad mínima con un valor de ajuste en % de la velocidad máxima.
  • Page 24 PARAM.NIVEL 2? PARAM.NIVEL 2? Acceso a configuración de parámetros avanzados < < SI SI ENTRAR PASSWORD: Introducir la contraseña de acceso específica del canal. Por defecto: 1 1 1 Es posible asignar una nueva contraseña al equipo (canal) CAMBIAR PASSWORD TIPO MOTOR No modificar <...
  • Page 25: Funcionamiento Con Accesorio Programador Horario Timer Rtc Ecowatt Junto Con El Accesorio Consola Prosys Ecowatt

    7. FUNCIONAMIENTO CON ACCESORIO PROGRAMADOR HORARIO TIMER RTC ECOWATT JUNTO CON EL ACCESORIO CONSOLA PROSYS ECOWATT Adquiriendo el programador horario TIMER RTC ECOWATT ofrecido como accesorio, se tendrá acceso a las funciones descri- tas en el apartado 6 Funciones Consola PROSYS ECOWATT , además de poder programar lo siguiente: •...
  • Page 26: Programación

    5. Encajar el componente electrónico presionando hacia abajo 7.2. PROGRAMACIÓN Durante el proceso de programación se deberán defi nir los siguientes parámetros: • T1, T2, T3: Hora de inicio para cada temporización (OFF,00:00-23:59) • Tiempo T1, Tiempo T2, Tiempo T3: La duración en minutos de cada temporización relacionada con su hora de inicio (hasta 480 minutos) •...
  • Page 27 + 3” Pulsar durante 3” Introducción fecha FECHA: 14/01/15 Aumentar / Disminuir valor Avanzar / retroceder HORA: Introducción hora 12:28 Presionando sobre SI se vuelve a pantalla inicial SALIR? CONT CONT LUNES Introducción hora inicio temporización T1 para el lunes 09:00 LUNES Introducción hora inicio temporización T2 para el lunes...
  • Page 28 TIEMPO T1 Introducción duración temporización T1 (0 – 480 min) Introducción duración temporización T2 (0 – 480 min) TIEMPO T2 15 m Introducción porcentaje sobre la consigna del modo de CONSIGNA T1 funcionamiento seleccionado (OFF,0-100%) Seguir secuencia FECHA INICIO Introducción fecha inicio periodo vacaciones 19/12/14 HORA INICIO Introducción hora inicio periodo vacaciones...
  • Page 29: Tabla Resumen Valores De Ajuste

    SALIR? Confirmar configuración SI SI Programacion Validación volcado programación <Pulsar tecla> 7.3. TABLA RESUMEN VALORES DE AJUSTE Registro Min. Max. Comentarios 23:59 Hora inicio temporización Tiempo T1 Tiempo T2 0min 480min Duración minutos temporización Tiempo T3 Consigna T1 Consigna T2 100% Porcentaje sobre la consigna Consigna T3...
  • Page 30: Mapa De Memoria Modbus

    El formato para cada byte en modo RTU es: • Sistema de códigos: 8–bit binario • Bits por Byte: 1 bit de START (inicio) 8 bits de datos, el bit más signifi cativo se envía el primero 1 bit para la paridad (Se requiere paridad par) 1 bit de STOP (fi...
  • Page 31 N°REG. Registro Min. Max. Descripción Por defecto Comentarios MinOut Incrementos 5% Valor salida mínima MaxOut Incrementos 5% Valor salida máxima Alarma entrada S1Alarm Incrementos 5% analógica 1 Alarma entrada S2Alarm Incrementos 5% analógica 1 MinRPM Incrementos de 100 Min RPM alarma VacMIN Incrementos de 10 Voltaje mínimo Motor AC...
  • Page 32 N°REG. Registro Min. Max. Descripción Por defecto Comentarios Inicio temporización 3 VIERNES T3 0x0000 0x063b Hora/Minuto 0x0480 viernes Inicio temporización 1 SABADO T1 0x0000 0x063b Hora/Minuto 0x0200 sábado Inicio temporización 2 SABADO T2 0x0000 0x063b Hora/Minuto 0x0300 sábado Inicio temporización 3 SABADO T3 0x0000 0x063b...
  • Page 33: Mantenimiento

    9. MANTENIMIENTO Antes de manipular el ventilador, asegúrese de que está desconectado de la red, aunque ya esté parado y de que nadie pueda ponerlo en marcha durante la intervención. Es necesaria una inspección regular del aparato. La frecuencia de la misma, debe ser en función de las condiciones de trabajo para evitar la acumulación de suciedad en hélices, rodetes, motores y rejillas que podría entrañar riesgos y acortaría sensi- blemente la vida del mismo.
  • Page 34 ENGLISH CONTENTS 1. INTRODUCTION ..................................35 2. SAFETY REGULATIONS AND “CE” MARKING ...........................35 3. GENERAL INSTRUCTIONS .................................35 4. DESCRIPTION ....................................35 4.1. Locations .....................................35 4.2. Wiring diagram and internal board ............................36 5. OPERATION WITHOUT PROSYS ECOWATT CONSOLE ......................37 6. OPERATION WITH PROSYS ECOWATT ACCESSORY CONSOLE ....................37 6.1.
  • Page 35: Introduction

    1. INTRODUCTION Thank you for purchasing this appliance. It has been manufactured in full compliance with applicable safety regulations and EU standards. Please read this instruction book carefully, as it contains important information for your safety during the ins- tallation, use and maintenance if this product. Keep it at hand for future reference.
  • Page 36: Important

    IMPORTANT At the bottom of the control box, two tubes (marked as “V” and “P”) come from the inside part of the fan. As the fan is supplied as constant pressure mode (COP), tube “P” is connected and “V” disconnected and blocked with a plastic stopper. To keep this confi...
  • Page 37: Operation Without Prosys Ecowatt Console

    Outputs Description Internal board power supply passing through ON/OFF switch (Factory wired) GND, N, (J2) RELÉ (J3) Commutate if any alarm is activated (2A maximum load) 0V, +V (J7) Output analog signal 0-10V to the motor TACOM (J8) Pulse motor A, B (J10) Network connection.
  • Page 38 Multiple control wiring diagram It is possible to connect up to 32 fans between them to create a communication network that can be adjusted and controlled with a single PROSYS ECOWATT console. IMPORTANT Before communication network is made, it is necessary to confi gure one by one all roof fan ECOWATT PLUS units, by assig- ning a different channel number to each one (From factory all the units are confi...
  • Page 39: Enter Password

    To change the fan number should follow these steps: 3” Press simultaneously for 3” Enter the password ENTER PASSWORD: Default: 1 1 1 CHANGE PASSWORD? It is possible to assign a new password to your device Selection on which cannel you want to set the fan SETUP MENU CAHNNEL N:1 FACTORY SETTING?
  • Page 40 Press on “OK” MAX-OUTPUT < 100% Press on “NO” SETUP LEVEL 2? < PROGRAM C:1? Press on “YES” to save changes < Program Press any key to return to main screen <Press any key • Turn off the device by ON/OFF switch in position “0” •...
  • Page 41: Description

    6.2. DESCRIPTION The PROSYS ECOWATT is used as a visualization and control supplement. Following functions are possible: • Display parameters and variables • Save settings • Display settings • Confi gure your device and operating modes • Search units (channels) in the network (previously each unit should be confi gured with different number of channels) The console has a LCD display of 2x16 characters, 4 buttons and 3 LED’s.
  • Page 42: General Parameters

    6.4. GENERAL PARAMETERS Once the wiring is done, turn on the device using the ON/OFF switch. When connecting the unit it will appear some screens: L L anguage: Langue: Sprache: Idioma: E E NGLISH H CASTELLANO FRANCAISE DEUTSCH After choosing the language, a screen with the following information will appear: S S i:xxxPa a S S c:100Pa a Si: xxx...
  • Page 43: Unit Confi Guration Via Console

    6.6. UNIT CONFIGURATION VIA CONSOLE 6.6.1. Change Set Point Steps to follow to change the set point from main screen: Measured value (units depend on operation mode) Set point Fan speed in % (on maximum speed) C: 1 Equipment number if connected to network 6.6.2.
  • Page 44: Operation Pi Pressure/Cop Mode

    At this time we are in confi guration mode and it is possible to navigate and select parameters desired: Pressing on “YES”, it is reloaded factory settings FACTORY SETTING? FACTORY SETTING? MODE MODE MODE MODE PI VOLUME MIN-MAX PROPORT. <PI PRESSURE OK MODE MODE PIPRESS+RTC...
  • Page 45: Motor Type

    Access to advanced configuration parameters SETUP LEVEL 2? SETUP LEVEL 2? < < Enter the password ENTER PASSWORD: Default: 1 1 1 It is possible to assign a new password to your device CHANGE PASSWORD (channel) MOTOR TYPE No modify <...
  • Page 46 Pulsar para modificar manualmente el RANGE parámetro. El valor que aparece en pantalla corresponde < 400Pa a la escala del sensor interno preajustado en fábrica. Si se instala un sensor externo, introducir el rango de escala correspondiente. SET POINT SET POINT SET POINT <IN1 0-10V OK <CONSOLE OK...
  • Page 47: Digital Input

    SP-2 PRESSURE Press to manually modify this parameter. This value corresponds to the % of pressure set point < being the fan in night mode. To connect a time clock or potential-free switch to the digital input J11 DIGITAL INPUT DIGITAL INPUT <...
  • Page 48 Once changed the operation mode to PI VOLUME/CAV, following parameters will appear: Press to manually modify the minimum MIN-OUTPUT output parameter to the motor < MAX-OUTPUT Press to manually modify the minimum output parameter to the motor < 100% Access to advanced configuration parameters SETUP LEVEL 2? SETUP LEVEL 2? <...
  • Page 49: Set Point

    SENSOR SENSOR SENSOR <IN1 0-10V OK <IN1 4-20mA OK < INTERNAL SENSOR SENSOR <IN2 4-20mA OK <IN2 0-10V OK Sensor: Sensor type - INTERNAL: Pressure differential internal sensor - IN1 0-10V: External sensor with analog signal 0-10V (J5 terminal) - IN1 4-20mA: External sensor with analog signal 4-20mA (J5 terminal) - IN2 0-10V: External sensor with analog signal 0-10V (J6 terminal) - IN2 4-20mA: External sensor with analog signal 4-20mA (J6 terminal) RANGE...
  • Page 50 PARAMETERS Press to manually modify this parameter. < Kp=100 It is advised not to modify. PARAMETERS Press to manually modify this parameter. < Ki=20 It is advised not to modify. SENSOR IN1 Press to manually modify this parameter. <SIN SENSOR OK It is advised not to modify.
  • Page 51: Operation Proportional/Vav Mode

    Press any key to return to main screen Program OK > <Pulsar tecla 6.6.5. Operation PROPORTIONAL/VAV mode In this mode the control box is ready to work with one or two analog inputs (4-20mA or 0-10V). The control box works according to the parameter of maximum demand.
  • Page 52 IN1 SET Press to modify manually the middle range of use. < 50%HR IN1 (+/-) Press to modify manually the width value of the adjustment range of the sensor < 25%HR Follow the same process if you select a different sensor type or activated the second input analog signal SENSOR Press to manually modify the minimum...
  • Page 53 MOTOR TYPE No modify < Press to modify manually this parameter. S1-ALARM This value allows you to send an alarm message when < measured by sensor IN1 value reaches a percentage of measuring range Press to modify manually this parameter. S2-ALARM This value allows you to send an alarm message when <...
  • Page 54: Min/Max Operation Mode

    6.6.6. MIN/MAX operation mode In this mode, the control box is ready to work by contact type normally open (NO) or normally closed (NC), located at the digital input J11. When the status of this input changes, the fan goes to low speed with a set value in % of maximum speed. Logic: •...
  • Page 55: Operation With Timer Rtc Ecowatt Accessory And Prosys Ecowatt Console Accessory

    MOTOR TYPE No modify < DIGITAL INPUT DIGITAL INPUT < (NC) < (NO) Digital input: - NC: Normally closed contact. The fan will pass to night mode when contact Digital input: is opened. - NC: Normally closed contact. The fan will pass to night mode when - NO: Normally open contact.
  • Page 56: Programming

    In order to do it correctly, follow these steps: 1. Disconnect power supply from the frontal ON/OFF switch 2. Open control box 3. Locate the J4 connector 4. Line up electronic component TIMER RTC ECOWATT with J4 connector pins 5. Fit the accessory pressing down 7.2.
  • Page 57 Example: MONDAY TUESDAY … SATURDAY SUNDAY 1:00 2:00 3:00 T3 = 480 min T3 = 480 min T3 = 480 min T3 = 480 min 4:00 SetpointT3 = 25% SetpointT3 = 25% SetpointT3 = 25% SetpointT3 = 25% 5:00 6:00 7:00 T1 = 60min T1 = 60min...
  • Page 58 MONDAY Start time for period frame T1 on Monday 09:00 MONDAY Start time for period frame T2 on Monday 11:00 MONDAY Start time for period frame T3 on Monday 14:00 TUESDAY Accepting, Monday scheduling is copied on Tuesday SAME? PERIOD T1 Time period introduction T1 (0 –...
  • Page 59 HOUR START Starting time holidays period 14:58 DATE END Ending date holidays period 30/12/14 HOUR END Ending hour holidays period 20:00 % over the set point for holidays period SET HOLIDAYS EXIT? Confirm settings Program Programming validation <Press any key>...
  • Page 60: Summary Table Setting Values

    7.3. SUMMARY TABLE SETTING VALUES Registro Min. Max. Description 23:59 Start time period frame Period T1 Period T2 0min 480min Period frame duration Period T3 Set T1 Set T2 100% Percentage over set point Set T3 Date start 00:00 23:59 Starting date holidays period Hour start 00:00...
  • Page 61 N°REG. Register Min. Max. Description Default Comments 0=Interno Sensor type in PI 1=IN1 0-10V PRESSURE or PI VOLUME SensorPI 2=IN1 4-20mA mode 3=IN2 0-10V 4=IN2 4-20mA 0=NO 1=0-10V %HR 2=4-20mA %HR Sensor type in 3=0-10V °C Sensor1 PROPORTIONAL mode 4=4-20mA °C and analog input signal 1 5=0-10V CO2 6=4-20mA CO2...
  • Page 62 N°REG. Register Min. Max. Description Default Comments %HR Increases Background scale in IN2 Range °C Increases proportional mode input 2 2000 PPM Increases Set point proportional IN1 Set IN1 Range Increases de 1 mode input 1 Margin (+/-) centered in IN1 Banda IN1 Range Increases de 1...
  • Page 63 N°REG. Register Min. Max. Description Default Comments DOMINGO T1 0x0000 0x063b Hour/Minute 0x0200 Starting period 1 Sunday DOMINGO T2 0x0000 0x063b Hour/Minute 0x0300 Starting period 2 Sunday DOMINGO T3 0x0000 0x063b Hour/Minute 0x0480 Starting period 3 Sunday Time in minutes for period TIEMPO T1 Time in minutes for period TIEMPO T2...
  • Page 64: Maintenance

    9. MAINTENANCE Before manipulating the fan, make sure it is disconnected from the mains supply even if it has previously been switched off. Prevent the possibility of anyone else connecting it while it is being manipulated. Fan unit must be regularly inspected. These inspections should be carried out bearing in mind the machine’s working condi- tions, in order to avoid dirt or dust accumulating on blades, impeller, motor or grids.
  • Page 65 FRANÇAIS SOMMAIRE 1. GÉNÉRALITÉS ....................................66 2. NORMES DE SECURITES ET MARQUAGE “CE” ........................66 3. NORMES GENERALES ................................66 4. DESCRIPTION ....................................66 4.1. Emplacements ..................................66 4.2. Branchement électrique et détail plaque interne ......................67 5. FONCTIONNEMENT SANS CONSOLE PROSYS ECOWATT ......................68 6. FONCTIONNEMENT AVEC ACCESSOIRE CONSOLE PROSYS ECOWATT ..................68 6.1.
  • Page 66: Généralités

    1. GÉNÉRALITÉS Avant d’installer et d’utiliser ce produit, lire attentivement ces instructions qui contiennent d’importantes indications pour votre sécurité et celle des utilisateurs, pendant l’installation, l’utilisation et l’entretien de ce produit. Une fois l’installation terminée, laisser ce manuel à la disposition de l’utilisateur fi nal. Dès réception, vérifi...
  • Page 67: Branchement Électrique Et Détail Plaque Interne

    IMPORTANT Dans la partie inférieure du boîtier de commande vous pourrez voir deux tubes repérés par les lettres « V » et « P » prove- nant de l’intérieur de l’extracteur de toit. L’équipement sort d’usine avec le tube marqué « P » connecté avec le tube « V » déconnecté...
  • Page 68: Fonctionnement Sans Console Prosys Ecowatt

    Sorties Descripción Alimentation plaque interne en passant par l'interrupteur (câblage en usine) GND, N, (J2) RELAIS (J3) Commute avec l'activation de toute alarme (charge maximale 2A) 0V, +V (J7) Sortie analogique 0-10V vers moteur TACOM (J8) Compte-tours moteur A, B (J10) Connexion à...
  • Page 69 Schéma de branchement contrôle multiple Il est possible de connecter jusqu’à 32 ventilateurs entre eux pour créer un réseau qui peut être ajusté et contrôlé avec une seule console PROSYS ECOWATT. IMPORTANT Avant de câbler le réseau de communi- cation, il est nécessaire de confi gurer de manière indépendante tous les extrac- teurs de toit ECOWATT PLUS, en attri- buant à...
  • Page 70: Mot De Passe

    Pour procéder au changement du numéro de ventilateur, procédez comme suit: 3” Appuyez simultanément pendant 3” Indiquez le mot de passe d’accès spécifique du canal. MOT DE PASSE: Par défaut: 1 1 1 MODIF. M.PASSE? Il est possible d’affecter un nouveau mot de passe à l’équipement Sélection du canal sur lequel vous souhaitez le ventilateur MENU CONFIG...
  • Page 71 Appuyez sur “OK” SORTIE-MAX < 100% Appuyez sur “NO” PARAM.NIVEAU 2? < PROGRAM C:1? Appuyez sur “OUI” pour enregistrer les modifications < Programmation OK Appuyez sur n'importe quelle touche pour revenir à > <Appuyer Touche l'écran de départ • Éteignez l’équipement grâce à l’interrupteur ARRÊT/MARCHE position “0” •...
  • Page 72: Description

    6.2. DESCRIPTION La console PROSYS ECOWATT est utilisée comme complément de visualisation et de contrôle. Elle permet de réaliser les fonctions suivantes: • Voir les paramètres et les variables de l’équipement • Enregistrer des confi gurations • Voir les confi gurations •...
  • Page 73: Paramètres Généraux

    6.4. PARAMÈTRES GÉNÉRAUX Une fois le branchement réalisé, alimentez le système au moyen de l’interrupteur arrêt/marche. Lorsque vous branchez l’appareil, l’écran suivant s’affi che: L L anguage: Idioma: Langue: Sprache: E E NGLISH H CASTELLANO FRANCAISE DEUTSCH Lorsque vous avez choisi la langue, un écran s’affi che avec les informations suivantes: Si:xxxPa a Sc:100Pa a Si: xxx...
  • Page 74: Confi Guration Des Équipements Par La Console

    6.6. CONFIGURATION DES ÉQUIPEMENTS PAR LA CONSOLE 6.6.1. Changement de Consigne Étapes à suivre pour modifi er le point de consigne à partir de l’écran principal: Valeur mesurée (les unités dépendront du mode de fonctionnement) Consigne Vitesse ventilateur en % (par rapport à la vitesse maximale) C: 1 Num.
  • Page 75: Parametres Usine

    Vous vous trouvez alors en mode confi guration et vous pouvez vous déplacer dans les paramètres de l’équipement, en confi - gurant le mode de travail: Appuyez sur « SI » pour recharger la configuration PARAMETRES USINE PARAMETRES USINE d'usine. FONCT.
  • Page 76 SORTIE-MAX < 100% Appuyez sur pour modifier manuellement le paramètre de sortie maximum au moteur Accès à la configuration de paramètres avancés PARAM.NIVEAU 2? PARAM.NIVEAU 2? < < Indiquez le mot de passe d'accès spécifique du canal. Par MOT DE PASSE : défaut : 1 1 1 Il est possible d'affecter un nouveau mot de passe à...
  • Page 77 PLAGE Appuyez sur pour modifier manuellement le paramètre. La valeur qui s'affiche à l'écran correspond < 400Pa à l'échelle du capteur interne préréglé en usine. Si un capteur externe est installé, introduisez la plage d'échelle correspondante. CONSIGNE CONSIGNE CONSIGNE <CONSOLE OK <IN1 0-10V OK <...
  • Page 78: Entree Digitale

    PARAMETRES Appuyez sur pour modifier manuellement le paramètre. Nous vous conseillons de ne pas le < Kp=100 modifier. PARAMETRES Appuyez sur pour modifier manuellement le paramètre. Nous vous conseillons de ne pas le < Ki=20 modifier. SONDE IN1 Appuyez sur pour modifier manuellement le paramètre.
  • Page 79: Programmation

    Enregistrer dans la mémoire les paramètres modifiés. PROGRAM C:1? < SI SI Appuyez sur n'importe quelle touche pour revenir à Programmation l'écran de départ > <AppuyerTouche 6.6.4. Fonctionnement mode PI DÉBIT /CAV Avant de sélectionner le mode de fonctionnement PI DEBIT par la console PROSYS ECOWATT, il est nécessaire de bien bran- cher les tubes de pression.
  • Page 80 Indiquez le mot de passe d'accès spécifique du canal. Par MOT DE PASSE : défaut : 1 1 1 Il est possible d'affecter un nouveau mot de passe à MODIF. M.PASSE? l'équipement (canal) TYPE MOTEUR Ne pas modifier < SONDE SONDE SONDE <IN1 4-20mA OK...
  • Page 81 CONSIGNE <IN2 4-20mA OK Consigne: - INTERNE: Valeur défi nie en usine - CONSOLE: Valeur réglée par console PROSYS ECOWATT - IN1/IN2 0-10V: Valeur ajustée par le potentiomètre externe (0-10V) - IN1/IN2 4-20mA: Valeur ajustée par le potentiomètre externe (4-20mA) Appuyez sur pour modifier manuellement CONSIGNE CONSOLE...
  • Page 82: Fonctionnement Mode Proportionnel / Vav

    ENTREE DIGITALE ENTREE DIGITALE < (NO) < (NF) Entrée numérique: Entrée numérique : - NF: Contact normalement fermé Le ventilateur passe en position nuit lorsque le con- - NF : Contact normalement fermé Le ventilateur passe en position tact est ouvert. - NO: Contact normalement ouvert Le ventilateur passe en position nuit lorsque le con- tact se ferme.
  • Page 83 Après avoir changé de mode de fonctionnement PROPORTIONNEL, les paramètres suivants s’affi chent: SONDE IN1 SONDE IN1 SONDE IN1 < 4-20mA%HR OK < 0-10V%HR OK <SANS SONDE OK SONDE IN1 SONDE IN1 < 4-20mATempOK < 0-10VTempOK SONDE IN1 SONDE IN1 <...
  • Page 84 SORTIE-MAX Appuyez sur pour modifier manuellement < 100% le paramètre. Accès à la configuration de paramètres avancés PARAM.NIVEAU 2? PARAM.NIVEAU 2? < < Indiquez le mot de passe d'accès spécifique du canal. Par MOT DE PASSE : défaut : 1 1 1 MODIF.
  • Page 85: Fonctionnement Mode Min-Max

    MIN RPM-ALARME Appuyez sur pour modifier manuellement le paramètre. Permet d'envoyer un message d'alarme < lorsque la valeur de régime du ventilateur arrive à une valeur minimale. IMPULSION Appuyez sur pour modifier manuellement < le paramètre. Nous vous conseillons de ne pas le modifier.
  • Page 86 SORTIE-MAX Appuyez sur pour modifier manuellement la valeur de sortie maximale. < 100% PARAM.NIVEAU 2? PARAM.NIVEAU 2? Accès à la configuration de paramètres avancés < < MOT DE PASSE : Indiquez le mot de passe d'accès spécifique du canal. Par défaut : 1 1 1 Il est possible d'affecter un nouveau mot de passe à...
  • Page 87: Fonctionnement Avec Accessoire De Programmation Horaire Timer Rtc Ecowatt Avec L'accessoire Console Prosys Ecowatt

    PROGRAM C:1? Validation paramètres modifiés < SI OUI Programmation OK Validation basculement programmation > <AppuyerTouche 7. FONCTIONNEMENT AVEC ACCESSOIRE DE PROGRAMMATION HORAIRE TIMER RTC ECOWATT AVEC L’ACCESSOIRE CONSOLE PROSYS ECOWATT En achetant le programmateur horaire TIMER RTC ECOWATT offert comme accessoire, vous aurez accès aux fonctions décri- tes au paragraphe 6, Fonctions Console PROSYS ECOWATT et vous pourrez programmer les données suivantes: •...
  • Page 88: Programmation

    4. Alignez le composant électronique TIMER RTC ECOWATT avec les pattes du connecteur J4 5. Encastrez le composant électronique en faisant pression vers le bas. 7.2. PROGRAMMATION Pendant la programmation défi nissez les paramètres suivants: • T1, T2, T3: Heure de début de chaque temporisation (OFF,00:00-23:59) •...
  • Page 89 IMPORTANT: Avant de commencer à confi gurer le programmateur horaire il est important de sélectionner le mode approprié. Voir pointe 6.6.1. Changement mode fonctionnement de ce manuel et choisissez l’un des modes suivants: PI PRESSION+RTC, PI DEBIT+RTC, PROPORTIONNEL+RTC o MAX-MIN+RTC. Pour commencer à...
  • Page 90 MARDI Acceptez pour copier la programmation du lundi MEME? TEMPS T1 Saisie durée temporisation T1 (0-480 min) Saisie durée temporisation T2 (0-480 min) TEMPS T2 15 m CONSIGNE T1 Saisie pourcentage sur la consigne du mode de fonctionnement sélectionné (OFF,0-100%) Suivre séquence DATE DEPART Saisie date début période vacances...
  • Page 91: Tableau Résumé Valeurs De Réglage

    Saisie pourcentage sur consigne période vacances CONSIGNE VAC SORTIR? Confirmer configuration SI SI Programmation OK Validation basculement programmation <AppuyerTouche> 7.3. TABLEAU RÉSUMÉ VALEURS DE RÉGLAGE Registre Min. Max. Commentaires 23:59 Heure début temporisation Temps T1 Temps T2 0min 480min Durée minutes temporisation Temps T3 Consigne T1 Consigne T2...
  • Page 92: Plan De Mémoire Modbus

    Message MODBUS Adresse Fonction Données Vérifi cation CRC 8 bits 8 bits Nx 8 bits 16 bits Le format pour chaque byte en mode RTU est: • Système de codes: 8-bit binaire • Bits par Byte: 1 bit de START (démarrage) 8 bits de données, le bit le plus signifi...
  • Page 93 N°REG. Registre Min. Max. Description Par défaut Commentaires (CTB/4-500/200) (CTB/4-800/250) (CTB/4-1300/315) Constante Débit avec capteur de Incréments 1 (CRVB-N 250) pression (CRHB/CRVB-N 280) (CRHB/CRVB-N 315) (CRHB/CRVB-N 355) (CTB/4-400/160) (CTB/4-500/200) (CTB/4-800/250) Numéros impulsions par retour PusionsEncodeur Incréments 1 (CTB/4-1300/315) de l’encodeur CRVB-N 250 CRHB/CRVB-N 280 CRHB/CRVB-N 315...
  • Page 94 N°REG. Registre Min. Max. Description Par défaut Commentaires LUNDI T1 0x0000 0x063b Heure / Minute 0x0200 Début temporisation 1 lundi LUNDI T2 0x0000 0x063b Heure / Minute 0x0300 Début temporisation 2 lundi LUNDI T3 0x0000 0x063b Heure / Minute 0x0480 Début temporisation 3 lundi MARDI T1 0x0000...
  • Page 95: Maintenance

    Input registers (lecture uniquement) N°REG. Registre Min. Max. Description Par défaut Commentaires Potentiomètre RV1 Pote Potentiomètre RV1 Entrée analogique 1 Entrée analogique 2 Entrée analogique 2 Entrée analogique 2 Interne 1250 Capteur pression int. Capteur pression interne Vitesse du moteur Régime 6000 Rpm moteur...
  • Page 96 S&P SISTEMAS DE VENTILACIÓN, S.L.U. C. Llevant, 4 Polígono Industrial Llevant 08150 Parets del Vallès Barcelona - España Tel. +34 93 571 93 00 Fax +34 93 571 93 01 www.solerpalau.com Ref. 9023053800-02...

Ce manuel est également adapté pour:

Crhb-n ecowatt plusCrvb-n ecowatt plus

Table des Matières