www.zephyronline.com
Verona
ZVO-E30AG
ZVO-M90AG
C
TM
+
Model number:
Airflow Control Technology
Serial Number:
OCT14.0801 © Zephyr Ventilation LLC.
For use with models of serial numbers beginning with 24

Publicité

Table des Matières
loading

Sommaire des Matières pour Essentials ZEPHYR Verona ZVO-E30AG

  • Page 1 All manuals and user guides at all-guides.com www.zephyronline.com Verona ZVO-E30AG ZVO-M90AG Model number: Airflow Control Technology Serial Number: OCT14.0801 © Zephyr Ventilation LLC. For use with models of serial numbers beginning with 24...
  • Page 2 All manuals and user guides at all-guides.com www.zephyronline.com...
  • Page 3 All manuals and user guides at all-guides.com SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ......................Mounting the Range Hood ........Ductless Recirculating ..........FEATURES & CONTROLS Touch Controls .............
  • Page 4 All manuals and user guides at all-guides.com www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 All manuals and user guides at all-guides.com WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION attics, crawl spaces or garages. OPERATION and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
  • Page 6: Parts Not Supplied

    All manuals and user guides at all-guides.com www.zephyronline.com MODELS: ZVO-E30AG & ZVO-M90AG PARTS SUPPLIED 1 - Hood with internal blower 2 - Aluminum mesh filters 1 - Duct cover assembly (top and bottom) 1 - Duct cover wall bracket 2 - 6W Zephyr Bloom LED light bulbs (pre-installed) ®...
  • Page 7 All manuals and user guides at all-guides.com Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7”...
  • Page 8 All manuals and user guides at all-guides.com www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible.
  • Page 9 All manuals and user guides at all-guides.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only.
  • Page 10 All manuals and user guides at all-guides.com www.zephyronline.com front of hood side of hood 12 13/16” 12 13/16” 11 15/16” STANDARD min. ducted - 26 1/2” min. recirc. - 31” max. - 50” Z1C-00VO min. ducted - 41 ” min. recirc. - 46” max.
  • Page 11: Cable Lock

    All manuals and user guides at all-guides.com CAUTION: At least two installers are required due to the weight and size of the hood. 2. Plum and mark center line. 11 1/8” not tighten all the way. Note: Wood blocking may need 14 3/4”...
  • Page 12 All manuals and user guides at all-guides.com www.zephyronline.com Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust circulated back within the home.
  • Page 13 All manuals and user guides at all-guides.com Display (speed level, delay off, filter clean/change,clean air) Power / Delay Off Lighted Glass Button clean mesh filter clean air replace charcoal filter Lights On/Dim/Off Adjust 6 Speed Levels 1 Power / Delay Off Button Power Button Function Button will turn power on and off for entire hood (fan and lights).
  • Page 14 All manuals and user guides at all-guides.com www.zephyronline.com Mesh Filter Clean Indicator (always enabled) - After 30 hours of fan usage the Graphic and words “ ” will illuminate indicating it is time to clean clean mesh filter the mesh filters. Graphic and words will remain illuminated until reset. - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “...
  • Page 15: Surface Maintenance

    All manuals and user guides at all-guides.com SURFACE MAINTENANCE: Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
  • Page 16 All manuals and user guides at all-guides.com www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR VERONA WALL Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON.
  • Page 17 All manuals and user guides at all-guides.com Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of hoods with Zephyr’s DCBL Suppression System without the need for expensive make up air kits.
  • Page 18 All manuals and user guides at all-guides.com www.zephyronline.com...
  • Page 19 All manuals and user guides at all-guides.com VOLTS MAX AMPS ZVO-E30AG, ZVO-M90AG CIRCUIT DIAGRAM ACT 590 CFM - Fan Max. 130W @ 1.8A ACT 390 CFM - Fan Max. 70W @ 1A ACT 290 CFM - Fan Max. 35W @ .55A...
  • Page 20 All manuals and user guides at all-guides.com www.zephyronline.com DESCRIPTION PART# Replacement Parts Optional Accessories Recirculating Kit ZRC-00VO Replacement Charcoal Filter Z0F-C002 Duct Cover Extension Z1C-00VO To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 21 All manuals and user guides at all-guides.com...
  • Page 22: Product Registration

    All manuals and user guides at all-guides.com www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service.
  • Page 23 All manuals and user guides at all-guides.com www.zephyronline.com Verona ZVO-E30AG ZVO-M90AG Numéro de modèle : _________________ Numéro de série : _________________ OCT14.0801 © Zephyr Ventilation LLC. Airflow Control Technology Pour une utilisation avec des modèles de numéros de série commençant par 24...
  • Page 24 All manuals and user guides at all-guides.com www.zephyronline.com...
  • Page 25 All manuals and user guides at all-guides.com MISE EN GARDE DE SÉCURITÉ ......LISTE DU MATÉRIEL ............INSTALLATION Feuille de calcul pour le conduit ......Espace libre et hauteur de montage ....Options d’installation pour le conduit ............Montage de la hotte ...........
  • Page 26 All manuals and user guides at all-guides.com LISEZ ET CONSERVEZ CES INSTRUCTIONS www.zephyronline.com AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 27 All manuals and user guides at all-guides.com ATTENTION POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
  • Page 28: Pièces Non Fournies

    All manuals and user guides at all-guides.com www.zephyronline.com MODÈLES : ZVO-E30AG & ZVO-M90AG PIÈCES FOURNIES 1 - Hotte avec ventilateur interne 2 - Filtre à tamis en aluminium 1 - Pièce de recouvrement de conduit (haut et bas) 1 - Support mural de recouvrement de conduit 2 - Ampoules DEL 6W 1 - Registre circulaire antirefoulement de 8”...
  • Page 29 All manuals and user guides at all-guides.com Equivalent number Equivalent number Duct pieces Duct pieces length x used T otal T otal length x used 3- 1/ 4” x 10” 1 Ft. 6”- 8” Round 30 Ft. Rect., wall cap straight with damper 7”...
  • Page 30: Conduit D'aération

    All manuals and user guides at all-guides.com www.zephyronline.com La hauteur de montage minimale ne devrait pas être moins de 26”. La hauteur de montage maximale ne devrait pas outrepasser 34”. Il est important d’installer la hotte à la hauteur x . C de montage adéquate.
  • Page 31: Avertissement De Risque D'incendie

    All manuals and user guides at all-guides.com AVERTISSEMENT DE RISQUE D’INCENDIE N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à...
  • Page 32: Dessus De La Hotte

    All manuals and user guides at all-guides.com www.zephyronline.com Devant de la hotte Côté de la hotte 12 13/16” 12 13/16” 11 15/16” STANDARD Min. avec conduit - 26 1/2” Min. avec reprise d’air - 31” max. - 50” Z1C-00VO Min. avec conduit - 41 ”...
  • Page 33 All manuals and user guides at all-guides.com ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. 1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A Support pour le (min.
  • Page 34: Ensemble De Reprise D'air (Requis Si Aucun Conduit N'est Utilisé)

    All manuals and user guides at all-guides.com www.zephyronline.com d’aération. Lorsque transformée, la hotte fonctionne comme une hotte de reprise d’air plutôt que comme un système Nous recommandons de TOUJOURS évacuer l’air à l’extérieur de la maison en utilisant le conduit en place ou, s’il y d’aération.
  • Page 35 All manuals and user guides at all-guides.com Touche de mise en Affichage (vitesse, arrêt automatique, nettoyage/changement marche/arrêt automatique des filtres, purification d’air) Touche de verre illuminé clean mesh filter clean air replace charcoal filter Lumières : Allumer/ Choix de six vitesses Veilleuse/Éteindre 1-Touche de mise en marche/arrêt automatique Fonction de mise en marche...
  • Page 36 All manuals and user guides at all-guides.com www.zephyronline.com Indicateur de nettoyage des filtres à tamis (toujours en fonction) - Après 30 heures d’utilisation du ventilateur, le symbole et les mots « clean mesh filter » s’illuminent, indiquant qu’il est temps de nettoyer les filtres à tamis. Le symbole et les mots restent illuminés jusqu’à la réinitialisation de la fonction. - Pour réinitialiser : Lorsque la hotte est éteinte, appuyez et tenez la touche enfoncée pendant trois secondes.
  • Page 37: Entretien Des Surfaces

    All manuals and user guides at all-guides.com ENTRETIEN DES SURFACES: Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces.
  • Page 38: Procédures De Dépannage Pour La Hotte Verona Wall

    All manuals and user guides at all-guides.com www.zephyronline.com PROCÉDURES DE DÉPANNAGE POUR LA HOTTE VERONA WALL Problème Cause Solution Après 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur l’installation, et de l’appareil est allumée l’appareil ne 2.
  • Page 39 All manuals and user guides at all-guides.com Certains codes locaux de limiter le montant maximum de CFM qu’une hotte de cuisinière peut se déplacer. ACT vous permet de contrôler le maximum CFM de les hottes avec le système de répression DCBL à partir de Zephyr sans avoir besoin de coûteux kits pour l’air de remplacement.
  • Page 40 All manuals and user guides at all-guides.com www.zephyronline.com Courbe de rendement du ventilateur, 390 CFM Entree en CA: 120V, 60 Hz Diametre du conduit de sortie : 8” Debit (pi3/min)
  • Page 41 All manuals and user guides at all-guides.com VOLTS MAX AMPS ZVO-E30AG, ZVO-M90AG SCHEMA DE CIRCUITS MOTEUR DEL DEL BRANCHEMENT DES COMMANDES CCI DES DEL INTERRUPTEUR CCI DES DEL CCI DES DEL BOÎTIER CCI DES COMMANDES CCI DES DEL HAUT LAMPE ACT 590 CFM - Ventilateur Max.
  • Page 42 All manuals and user guides at all-guides.com www.zephyronline.com DESCRIPTION DE PIÈCE Pièces de remplacement Ampoule DEL 6W (chaque) Z0B-0034 Filtre à tamis en aluminium (chaque) 50200045 Accessoires optionnels Ensemble de reprise d’air ZRC-00VO Filtre à charbon de remplacement Z0F-C002 Ensemble de prolongement de recouvrement de conduit Z1C-00VO Pour commander des pièces, visitez-nous en ligne au www.zephyronline.com ou communiquez avec nous par téléphone au 1-888-880-8368...
  • Page 43 All manuals and user guides at all-guides.com...
  • Page 44: Enregistrment Du Produit

    All manuals and user guides at all-guides.com www.zephyronline.com ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente.

Ce manuel est également adapté pour:

Zephyr verona zvo-m90ag