6. Ceiling Mounting
Fig.5 Ceiling hole pattern
Cut/drill hole pattern in ceiling as shown in (fig.5) (Note: fixings for hole (A) are not supplied by
Dedicated Micros due to the variation of ceiling materials / thicknesses found on site. Please
choose suitable M6 fixings, with countersunk head, for your application.) Attach mounting disc (B)
to ceiling with chosen fixings and screw 4 off M6 x 16 soc cap hd. screws supplied into bushes as
shown (C). Attach transfer disc (E) to top of dome enclosure (G) with 4 off M6 dome hd. self tapping
trilobular screws (D) pre-fitted (fig.6) (Note: Fit safety bond bracket (F) as shown) Offer dome
enclosure to ceiling mounting disc (fig.7) engaging the screw heads (C) into keyhole slots (G).
Twist to locate and tighten fixings (C) to secure.
Please ensure safety bond is fitted as descibed on sheet 4.
D
E
G
Fig. 6
2060 Operation Manual
A
4 x Ø6.5mm
C
B
D
F
Fig. 7
G
Page. 5