Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleaning

On an annual basis, maintenance is required to ensure TrueDRY runs at peak efficiency.
Unplug TrueDRY DH150 before beginning
1
service. Push down the door release and
pull. The filter can be removed from either
side.
Using a 1/2-in. hex drive or standard screw-
driver, remove the eight screws on either
3
side of the TrueDRY DH150. The side and
top panels can then be removed. Using a
damp cloth, wipe excess dust and debris
from blower, refrigerant coils, and compres-
sor coils. Reattach panels and collars when
finished.
Grip filter tab at bottom to remove.
2
Replace with new filter.
Check the drain connection and drain line
to ensure it is clear of debris and sludge.
4
Ensure all hose connections are secure once
maintenance of the drain lines is complete.
When service is complete, initiate a call for
dehumidification and check that the com-
5
pressor and fan activate. If using the digital
VisionPRO IAQ or TrueIAQ controls, reset
maintenance reminders.
11
TrueDRY DH150
69-2271EFS—01

Publicité

Table des Matières
loading

Table des Matières