If the dome is being controlled via an external protocol converter (DAX-DEN or DRX100) then the
dome's internal video gain should be set to Video gain1 / normal and set the Video lift off. These
setting are accessed through the Technician Menu by selecting the Miscellaneous Services
option followed by the Video amp settings.
On Baxall controllers, alphabet menu appears when the joystick is touched.
This is because the Baxall controller has been configured to "Alternate " mode, it should be set to
"Standard" mode with Rx as "dc", NOT a.c.
On Dedicated Micros & BBV controllers the Dome spins continuously
This could be due to there being no "dead band" on the joystick, caused by the joystick being off
centre on power up. Power the controller down then power up again ensuring that the joystick is
free to self-centre.
To reset the dome (If the menu can be accessed)
This is done by accessing the dome Technician menu and selecting Miscellaneous services,
followed by NVM Services. Reload factory defaults will reset the dome to the original factory
settings. Note, however, that it will also remove all preset positions and tours from the memory.
This procedure should take about 40 seconds.