1. SPECIFICATIONS

1.1 Technical specifications

Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Performance
Nominal output
Power range
Average CO concentration at 13% of O
NOx concentration at 13% of O
OGC concentration at 13% of O
Particle concentration at 13% of O
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Flue duct
Ø Air inlet
Front safety distance
Side safety distance
Back safety distance
Base safety distance
Average temperature of smoke
Type of combustion
Flue liner
Fuel
Humidity fuel logs
Certification year
Certificate No.:
1.2 Breakdown of delivery components
(
Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1. Fireplace's body.
2. Direct flue pipe.
3. Ceiling crest.
4. Aluminium ring to connect, exterior air inlet cover and metal clamp.
5. Heat-resistant spray paint for touch-ups.
6. Bag with: 4x anchors and 4x screws.
7. Tool to install flue pipe.
8. Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
9. Heat-resistant glove.
10. Tool for handling registers.
11. Cleaning cloth.
12. Ceramic adhesive rope.
13. Bag with: 8x screws
14. Bag with: 6x metal anchors
15. Upper baffle to limit the draught.
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. In case it is installed with the optional foot support, make sure the ground where the appliance will be placed is able to
support the weight of the device. If not, you will need a load spreading plate for the equitable distribution of the equipment's weight.
In case of doubt, please consult a specialist.
2
2
2
2
Ronde Frontal
11-13 Pa
2,44 kg/h
7,7 g/s
89 %
9,7 kW
7 – 11,5 kW
0,094 %
3
105 mg/Nm
3
66 mg/Nm
3
24,3 mg/Nm
12,3 Pa
155,5 kg
3,5 kg
200 mm
250 mm
4000 mm
Ø 180 mm
120 mm
1000 mm
400 mm
150 mm
300 mm
150,8 º C
INTERMITTENT
NOT SHARED
NATURAL WOOD
12-20% - two years under cover
2020
1880-CPR-079-20