TESTING & ADJUSTMENT
TO TEST
Make sure all control valves are in the "OFF" position.
Apply the soap solution described above to all fittings.
Turn the gas supply on.
Check all connections from the supply line, or LP cylinder up to and including the manifold pipe
assembly.
Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas supply,
tighten any leaking fittings, turn the gas supply back on, and recheck.
If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased your
side burner.
Do not use the side burner until all connections have been checked and do not leak.
IMPORTANT NOTE - ALWAYS CHECK FOR LEAKS AFTER EVERY LP CYLINDER CHANGE.
IMPORTANT NOTE - ALWAYS CHECK FOR LEAKS AFTER EVERY LP CYLINDER CHANGE.
BURNER / VALVE ADJUSTMENTS
Consult the GAS CONNECTIONS section of your Hestan outdoor appliance for full instructions on
burner adjustments, flame appearance, and valve adjustments. This step is very important to ensure
successful burner performance after conversion to the new fuel type, or changing orifices for high
altitude locations.
NG IS 7" SUPPLY --> 4" AT MANIFOLD
LP IS 11" SUPPLY --> 10" AT MANIFOLD
Equipment
Single Outdoor
Side Burner
Double Outdoor
Side Burner
LABEL
After conversion, the label below must be attached to the appliance next to the existing rating label. The
qualified service technician will fill in the Gas Type, Manifold Pressure, and BTU Rates for each burner
type (per the chart above). The technician should sign and date the label as well.
(continued)
Side Burner Orifice Chart
Rate Per
Gas
Burner Type
Burner
Type
(Btu/hr)
Front (main)
NG
20,000
Front (simmer)
NG
Front (main)
LP
18,000
Front (simmer)
LP
Front (main)
NG
20,000
Front (simmer)
NG
Front (main)
LP
18,000
Front (simmer)
LP
Rear (main)
NG
10,000
Rear (simmer)
NG
Rear (main)
LP
10,000
Rear (simmer)
LP
ORIFICE SIZE
Orifice P/N
-NG
-LP
45
-
008666-045
65
-
008666-065
-
56
008665-056
-
75
008665-075
45
-
008666-045
65
-
008666-065
56
-
008665-056
-
75
008665-075
54
-
008666-054
67
-
008675-067
-
65
008665-065
-
76
008675-076