2.8
PRIMING (On demand)
With the switch on MOM position, the pump runs at maximum speed until the key is released.
P r
The display shows:
Priming is "transparent":
1) The time continues if dosing is timed.
2) When priming has finished, the speed returns to the dosing speed.
3) If priming is enabled to run outside of the dosing period, when the operation has finished the pump returns to the
previous state.
2.9 MOTOR BLOCK
In case the motor is excessively overloaded (for ex. a tubing breaks) the pump executes stop/restart motor cycles (the stop
time increases at every STOP: 0.5 sec . 10 sec.) to avoid the overheating of the same pump.
During the motor stop the display visualizes:
2.10
LEVEL ALARM (On demand)
If the pump signals a level alarm, the display shows:
3 DISPLAY
a)
As soon as the pump is powered, the display shows
runs a check
:
If the parameters cannot be read properly from EEPROM, the display shows FAIL and the pump remains on standby.
The default parameters can be reset using the UP key (pressed and hold down for 4 seconds).
The default parameters are:
After resetting the default parameters, the pump reinitializes and starts with the default settings (which can then, obviously,
be changed by accessing the programming menu).
b)
During RINSE dosing the display shows
c)
During CHARGE dosing the display shows:
d)
When dosing has finished, the display shows the word END for machines with 2 SV:
For machines with 1 SV, rather, END is shown only after the CHARGE program has finished; after the RINSE
program, the display continues to show the following for the T_WAIT – T_RINSE time:
e)
During priming the display shows:
f)
During standby the display shows:
P_ _ _ Password to access the programming menu
1
V Charge speed (10 – 100%)
2
V Rinse speed (10 – 100%)
3
T Charge time (0 – 999 sec)
4
T Rinse time (0 – 999 sec)
5
T Wait time (0 – 999 sec)
6
Speed enable/disable in On line mode (ON - OFF)
o
Password setting
Hid
Exit menu saving settings
ESC
Exit menu without saving settings
MINI-PRO DD
1 A L r
2 A L r
Vcharge = 100
Vrinse = 100
Tcharge = 20
(1 SV MODE)
Password = 000
ON Line mode = ON
: r I n
c H r
Pr
SbY
SUMMARY TABLE
0000137164
rev. 1.0
. The buzzer is activated.
8888
for approximately 0.3 seconds, during which the pump
Trinse = 20
Twait = 25
End
rIn
Page 4/4