SET UP INSTRUCTIONS
Place dehumidifier in upright position. After transporting
dehumidifier to site, allow unit to sit for 30 minutes before
powering ON. This allows the refrigerant system time to
stabilize and avoid damage.
WARNING:
Do not block air inlet or outlet. Do not attach ductwork.
AIR INLET
KEEP CLEAR
PROPER DRAINAGE
This dehumidifier contains a built-in pump that connects
to a draining hose in the back of the unit.
1. Ensure that external water does not create a slipping
hazard.
2. To avoid pump damage or overuse, do not exceed 10
foot vertical lift between pump and drain.
OPTIONAL FUNCTIONS:
When the
key is pressed
you will see:
While navigating through
some functions, it may
also display:
Your unit may not contain these functions, which are
OPTIONAL. If not, an error message will be displayed
when access is attempted.
DEFROSTING MODE
To ensure dehumidifier operates at its most efficient
condition, unit will be in defrosting mode when ambient
temperature falls below 77°F (25°C). Defrost controls
are listed below:
• Continuous working time is equal to ambient temperature
x2; minimum working time is 30 minutes.
• If temperature of indoor coil is ≤26.6˚F(-3°C) after
continuous working time is reached (continuous detection
30s), unit will enter defrost mode for 5 minutes.
• When temperature of indoor coil is ≥46.4˚F(8°C) during
defrost mode, unit will exit defrost mode.
LGR Dehumidifier Low-Grain Refrigerant
200 Pints Per Day Water Pump
Illustration of correct
positioning for best
performance
AIR OUTLET
KEEP CLEAR
Drain Hose
10 FT. MAXIMUM
DRAIN HEIGHT
Humidity Setting
Timer
Clock
Language ID
USB/SD-CARD GSM
DIGITAL CONTROL PANEL
ADJUSTMENT KEYS
These 2 keys allow you to adjust humidity values
and time settings (up or down).
NOTE: To cycle through menu functions, you must
press BOTH adjustment keys at the same time
FUNCTION
Displays menu of unit functions. To cycle through
menu functions you must press BOTH up and
down adjustment keys at the same time
ENTER
Selects and activates a function or setting.
PURGE
Empties the water reservoir.
POWER ON/OFF
Turns the unit ON and OFF.
OPERATION
Starting the unit
1. Turn the power ON
Press the "Power ON/OFF" key once to
turn the power ON.
2. Set TIME and DATE
Press the
key once to display:
Press both
to highlight "Clock."
Press
to enter clock settings:
Press
OR
to desired hour, then
to access minutes.
Repeat
together to access year, month, and day.
Press
when done to exit clock settings.
NOTE: This unit has an internal battery powered clock, so
you do NOT need to set the time and date every time you
plug it in or turn power ON.
Setting the humidity
Unit is factory set for CONTINUOUS OPERATION
("CO"), if no humidity adjustments are made or if you set
a humidity level below 26%, see below:
To adjust the relative humidity level from 26% to 90%
press
once.
Press the
key to select
"Humidity Setting."
2
User Manual
Humidity Setting
Timer
keys together TWICE
Clock
Y0000 M00 D00
Humidity Setting
Timer
Clock
Clock
00:00
together