2-1. Specifications

NOTE
Amperes Input at
60 Hz, Single-Phase
115 V
(+15%)
Rated Output
27 A at 92 Volts DC At
28 max;
35% Duty Cycle
*While idling

2-2. Specifications For Torch

Air-cooled torch for plasma arc cutting (PAC)
35% duty cycle
Safety interlock devices shut down power source
Safety trigger guard
Cutting capacity: see Section 2-1

2-3. Duty Cycle And Overheating

3-1/2 Minutes Cutting
Overheating
SECTION 2 – INSTALLATION
If the unit is operated from a 30 ampere, 115 volt circuit or a 15 ampere, 230 volt
circuit, a different input power plug must be installed on the power cord. See
Section 2-9 for instructions.
Rated Output,
230 V
115 V
(+15%)
KVA/KW
14 max;
3.32 KVA
0.30*
0.13*
3.25 KW
For Units Connected to a 115 Volt Circuit
or a 230 Volt Circuit:
35% Duty Cycle At 27 amperes, 92 volts dc
35% duty cycle
0
15
Minutes
230 V
Plasma
KVA/KW
Gas
Air Or
3.25 KVA
Nitrogen
3.19 KW
Only
6-1/2 Minutes Resting
Rated
Plasma
Plasma
Cutting
Gas Flow/
Capacity
Pressure
at 10 IPM
4.5 CFM
(129 L/min)
3/8 in
At 60 PSI
(10 mm)
(414 kPa)
Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, Temperature
trouble light goes On, and cooling
fan runs. Wait fifteen minutes for
unit to cool or temperature light to
go off. Reduce amperage or duty
cycle before cutting or gouging.
Y Exceeding duty cycle can
damage
unit
and
warranty.
A
OR
Reduce Duty Cycle
sduty1 5/95 / 802 784
OM-203 653 Page 9
Max
OCV
288 Volts
DC
void