When battery terminals are reverse connected, the fuse will blow to protect appliances.
Overheat Protection
When the heat sink temperature exceeds 45°C, the inner cooling fan will switch on automatically to cool the inverter.
When the internal temperature exceeds 70°C, the AC output will shut off automatically and the ALARM/WARNING light will turn red. The unit
will be unusable for 15 minutes.
6. TROUBLESHOOTING REFERENCE
Acoustic buzzer alarms
When using the inverter with acoustic devices, some inferior acoustic devices will buzz, as the output wave from the inverter is a modified
sine wave inverter.
TV Interference
You can reduce interference to a minimum by using a filter. On occasions when the interference of weak signals becomes too obvious, you
can try the following:
Place the inverter some distance away from the TV and TV antenna.
Try to change the direction of the TV signal cable and TV antenna to reduce interference to a minimum.
Use a high-quality screen cable antenna.
Problem: No output voltage
POSSIBLE CAUSES
Battery voltage too low
Overload
Inverter thermal protection
Inverter start-up fail
Reverse polarity connection and fuse melted
Problem.· Inverter no response
POSSIBLE CAUSES
Poor contact between battery and inverter
Reverse polarity connection and fuse melted
Problem.· Output voltage low
POSSIBLE CAUSES
Input voltage too low
Overload
Problem.· Low voltage alarm
POSSIBLE CAUSES
Battery no power
Battery voltage too low or poor connection
7 SPECIFICATIONS
ITEMS
Continuous power
Surge Power
Dimensions (L x W x H)
Packing
PCS/CTN
KGS/CTN
MEAS (L x W x H) cm
0510350-62i_A5.indd 5
0510350-62i_A5.indd 5
SOLUTION
Recharge or replace the battery
Reduce the load
Cool the inverter and position it in a well-ventilated area; Reduce the load
Try starting the inverter again
Replace the fuse with a fuse of equivalent value
SOLUTION
Reconnect the battery and inverter
Replace the fuse with a fuse of equivalent value
SOLUTION
Make sure the input voltage is within the rated range.
Reduce the load
SOLUTION
Recharge the battery
Recharge the battery, check terminal connections or clean terminal with a dry cloth
MODEL
0510350
0510351
150W
300W
300W
600W
120 x 100 x 50
120 x 100 x 50
16
16
14.8
15.0
44 x 38 x 34
44 x 38 x 34
0510352
0510353
600W
IOOOW
1200W
2000W
150 x 100 x 55
210 x 150 x 70
16
6
19.0
15.4
44 x 38 x 34
42 x 34 x 45
0510354
1500W
3000W
310 x 150 x 70
4
12.6
44 x 42 x 33
08-07-2020 08:10
08-07-2020 08:10

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0510351051035205103530510354

Table des Matières