Impostazione Dei Dip Di Configurazione Pag; Configurazione Di Default Pag; Setting The Configuration Dipswitches; Default Configuration - Sabiana IRC board-remote Notice D'utilisation

Table des Matières

Publicité

CONfIgURAzIONE
1
2
Impianto a 4 tubi
ON
x
Impianto a 2 tubi
OFF *
x
Esclusione T3
x
ON *
Sonda di minima T3 attiva
x
OFF
Senza telecomando
x
x
Con telecomando
x
x
Ventilazione continua
x
x
Autofan in raffreddamento
x
x
Autofan in riscaldamento
x
x
Autofan sempre
x
x
Senza valvole
x
x
(ON-OFF sul ventilatore)
Con post-ventilazione
x
x
3 minuti
Senza post-ventilazione
x
x
Unità Master
x
x
Unità Slave
x
x
x = Non importante per la specifica funzione
Not important for the specific function
Pas important pour la fonction spécifique
* = Configurazione di default

Default configuration

Configuration par défaut
C
non Vi sia Presenza
onfigurazione raCComandata nel Caso
C
WATER VALVES ARE NOT USED
onfiguration reCommended if the
C
'
N'y A PAS
onfiguration reCommandée s
il
r
aggiunto il Valore di temPeratura imPostato
il motoVentilatore Viene Portato in
o
nCe the set temPerature has been reaChed
off
switChed
without any Post
l
orsQue la temPérature Programmée est atteinte
off
met sur
sans auCune Post
IMPOSTAzIONE
DIP DI CONfIgURAzIONE
Posizione Switches
3
4
5
6
7
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
ON
x
x
x
x
OFF *
x
x
x
x
x
ON *
x
x
x
x
OFF
ON
OFF *
x
x
OFF
OFF *
ON
x
x
OFF
ON
ON
x
x
OFF
ON
ON
ON
x
x
x
x
OFF *
x
x
x
x
ON
x
x
x
x
x
x
x
x
x
x
ValVole aCQua
delle
VANNES D'EAU
de
,
off
-
.
senza alCuna Post
Ventilazione
,
-
the motor
driVen fan is
-
.
Ventilation
,
le Ventilateur se
-
.
Ventilation
CONfIgURAzIONE DI DEfAULT
-
Ventilazione continua.
-
Termostatazione (ON/OFF) delle/a valvole/a
acqua.
-
T3 disattivata.
Nota: la sonda T3 (di minima temperatura) è
montata; se si vuole attivarne il funziona-
mento, porre il Dip 2 in OFF.
8
SETTINg ThE CONfIgURATION
DIPSWITChES
CONfIgURATION
8
x
4-pipe system
2-pipe system
x
x
Disable T3
Enable T3 cut-out thermostat
x
Without remote control
x
x
With remote control
Fan always on
x
Autofan in cooling
x
x
Autofan in heating
Autofan always
x
Without valves
x
(ON-OFF on the fan)
With post-ventilation
x
3 minutes
Without post-ventilation
x
Master unit
ON
OFF *
Slave unit
CONfIgURATION
Installation 4 tubes
Installation 2 tubes
Exclusion T3
Sonde de limitation T3 basse
Sans télécommande
Avec télécommande
Ventilation continue
Autofan en refroidissement
Autofan en chauffage
Autofan toujours
Sans vannes
(ON-OFF sur le ventilateur)
Avec post-ventilation
3 minutes
Sans post-ventilation
Unité Maître
Unité Esclave
DEfAULT CONfIgURATION
-
Fan always on.
-
Temperature control (ON/OFF) on the water
valve/valves.
-
T3 disabled.
Note: probe T3 (cut-out thermostat) is already
fitted; to enable the operation of the probe,
set dipswitch 2 to OFF.
PROgRAMMATION
DES DIPSWITChES
Switch position
1
2
3
4
5
6
ON
x
x
x
x
x
OFF *
x
x
x
x
x
x
ON *
x
x
x
x
x
OFF
x
x
x
x
x
x
ON
x
x
x
x
x
OFF *
x
x
x
x
x
x
ON *
x
x
x
x
x
OFF
ON
OFF *
x
x
x
OFF
OFF *
ON
x
x
x
OFF
ON
ON
x
x
x
OFF
ON
ON
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Position Switches
1
2
3
4
5
6
ON
x
x
x
x
x
OFF *
x
x
x
x
x
x
ON *
x
x
x
x
x
OFF
x
x
x
x
x
x
ON
x
x
x
x
x
OFF *
x
x
x
x
x
x
ON *
x
x
x
x
x
OFF
ON
OFF *
x
x
x
OFF
OFF *
ON
x
x
x
OFF
ON
ON
x
x
x
OFF
ON
ON
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
CONfIgURATION PAR DEfAUT
-
Ventilation continue.
-
Thermostatation (ON/OFF) de la (des)
vanne(s) eau.
-
T3 désactivée.
Note: la sonde T3 (limitation basse) est montée;
si on veut en activer le fonctionnement
mettre le Dip 2 sur OFF.
8A
7
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
ON
x
OFF *
x
ON
x
x
ON
x
OFF *
7
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
ON
x
OFF *
x
ON
x
x
ON
x
OFF *

Publicité