Oase AquaMax Eco Classic 2500 Notice D'emploi page 12

Masquer les pouces Voir aussi pour AquaMax Eco Classic 2500:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
- GB -
Aquamax Eco Classic 2500
Installation
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
Operating the unit in the pond
B
The pump is in the pond. The return system, e.g. a pond filter, is connected to the pump outlet.
8.
How to proceed:
0.
C
1. Screw the stepped hose adapter to the outlet.
2. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
− This reduces pressure losses.
3. Connect the hose with the stepped hose adapter and secure with a hose clip.
Aquamax Eco Classic 3500/5500/8500/11500/14500/17500
Installation
The unit can be placed submerged or dry.
Always place the unit below water level.
Place the unit horizontally on the ground ensuring its stable position.
Operating the unit in the pond
B
The pump is in the pond. The return system, e.g. a pond filter, is connected to the pump outlet.
4.
How to proceed:
0.
D
1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
2. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
− This reduces pressure losses.
− Align the stepped hose adapter prior to tightening the union nut.
3. Connect the hose with the stepped hose adapter and secure with a hose clip.
Install the unit at a dry place
E
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
4.
How to proceed:
0.
F
1. Remove screws.
− The screws are used as transport protection and not required for operation.
2. Actuate the engagement hook and fold up the strainer top casing.
3. Remove pump.
4. Screw the stepped hose adapter including sealing ring onto the inlet.
5. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
− This reduces pressure losses.
6. Connect the hose with the stepped hose adapter and secure with a hose clip.
− Align the stepped hose adapter prior to tightening the union nut.
7. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
8. Shorten the stepped hose adapter to the diameter of the hose used if necessary.
− This reduces pressure losses.
− Align the stepped hose adapter prior to tightening the union nut.
9. Connect the hose with the stepped hose adapter and secure with a hose clip.
12

Publicité

Table des Matières
loading

Table des Matières