EAS ELECTRIC M-THERMAL 2 R32 BIBLOCK ETHKH100A190 Guide D'utilisation page 71

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2 COOL MODE SETTING
2.1 COOL MODE
2.2 t_T4_FRESH_C
2.3 T4CMAX
2.4 T4CMIN
2.5 dT1SC
ADJUST
2 COOL MODE SETTING
2.6 dTSC
2.7 t_INTERVAL_C
2.8 T1SetC1
2.9 T1SetC2
2.10 T4C1
ADJUST
2 COOL MODE SETTING
2.11 T4C2
2.12 ZONE1 C-EMISSION
2.13 ZONE2 C-EMISSION
ADJUST
8.4.3 HEAT MODE SETTING
Go
to
MENU>FOR
SERVICEMAN>
MODE SETTING.
Press
pages will be displayed:
3 HEAT MODE SETTING
3.1 HEAT MODE
3.2 t_T4_FRESH_H
3.3 T4HMAX
3.4 T4HMIN
3.5 dT1SH
ADJUST
3 HEAT MODE SETTING
3.6 dTSH
3.7 t_INTERVAL_H
3.8 T1SetH1
3.9 T1SetH2
3.10 T4H1
ADJUST
3 HEAT MODE SETTING
3.11 T4H2
3.12 ZONE1 H-EMISSION
3.13 ZONE2 H-EMISSION
3.14 t_DELAY_PUMP
ADJUST
8.4.4 AUTO MODE SETTING
Go to MENU> FOR SERVICEMAN> 4.AUTO MODE
SETTING. Press OK, the following page will be
displayed.
4 AUTO. MODE SETTING
4.1 T4AUTOCMIN
4.2 T4AUTOHMAX
ADJUST
1/3
YES
2.0HRS
43°C
20°C
5°C
2/3
2°C
5MIN
10°C
16°C
35°C
3/3
25°C
FCU
FLH
3.HEAT
OK.
The
following
1/3
YES
2.0HRS
16°C
-15°C
5°C
2/3
2°C
5MIN
35°C
28°C
-5°C
3/3
7°C
RAD.
FLH
2MIN
25°C
17°C
8.4.5 TEMP. TYPE SETTING
About TEMP. TYPE SETTING
The TEMP. TYPE SETTING is used for selecting whether the
water flow temperature or room temperature is used to
control the ON/OFF of the heat pump.
When ROOM TEMP. is enabled, the target water flow
temperature will be calculated from climate-related curves.
How to enter the TEMP. TYPE SETTING
Go to MENU> FOR SERVICEMAN> 5.TEMP. TYPE SETTING.
Press OK. The following page will be displayed:
5 TEMP. TYPE SETTING
5.1 WATER FLOW TEMP.
5.2 ROOM TEMP.
5.3 DOUBLE ZONE
ADJUST
If you only set WATER FLOW TEMP. to YES, or only set
ROOM TEMP. to YES, The following pages will be
displayed.
only WATER FLOW TEMP. YES
If you set WATER FLOW TEMP. and ROOM TEMP. to
YES, meanwhile set DOUBLE ZONE to NON or YES, the
following pages will be displayed.
Homepage (zone 1)
In this case, the setting value of zone 1 is T1S, the setting
value of zone 2 is T1S2 (The corresponding TIS2 is
calculated according to the climate related curves.)
If you set DOUBLE ZONE to YES and set ROOM TEMP. to
NON, meanwhile set WATER FLOW TEMP. to YES or
NON,the following pages will be displayed.
Homepage (zone 1)
31
YES
NON
NON
only ROOM TEMP. YES
2
Addition page (zone 2)
(Double zone is effective)
2
Addition page (zone 2)
V.2