Care Instructions - Weka 533.2020 Instructions De Montage, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
CAUTION
Contrary to the notes in the installation instructions for the sauna controller, the stove or bench sensors are to be
attached to the sauna ceiling. After the first ceiling panel has been laid loosely on the ceiling supporting timbers, the
cables are laid above the ceiling panel (figure 22) as far as the sauna room. The ceiling panel is then drilled through
as shown in the following figure (Ø 10 mm each).
This change has been made in consultation with the manufacturer of the sauna controller.
Klassik OS
Plan view
Stove sensor
CAUTION
The electric cable for connection to the mains supply (not included in the scope of delivery) must not be laid within the
sauna walls. The mains supply cable is connected to the silicone cable (Si1), which runs out through the rear wall of
the sauna cabin (approx. 223-237 cm above the foundation) as shown in Fig. 22.2.
Safety tips
Please note that children should not be permitted unsupervised in the cabin.
Do not place any objects on the sauna stove. – FIRE HAZARD!
Before beginning the heating phase, make sure that there are no flammable objects in the vicinity of the stove.
Use the sauna infusion concentrate in diluted form only.
Instructions on the correct use can be found on the containers.
Always use wood glue, never chemical adhesives, inside the sauna.
After using the sauna allow it to cool down by leaving the door open.
The information sign is to be fixed in a clearly visible position near the sauna stove.
CAUTION
It must always be easy to open the sauna door from the inside. For safety reasons, the retrofitting of a door lock or
similar locks resulting in external locking is prohibited.

Care instructions

In order to enjoy the cabin for a long time, it should be cleaned regularly.
The unbeatably mild and agreeable sauna climate is achieved by the thermal storage properties of solid wood.
The interior wooden parts may not be surface treated.
If the cabin is not to be used for longer period of time, we recommend that it is heated at least once a month for half
an hour.
It is unavoidable that small amounts of resin will appear on the surface of the wood.
The dry resin residues can be removed with fine sandpaper.
BioAktiv BIOS
Plan view
Stove sensor
Bench
sensor
Sauna
light
SAUNAWORLD
No sweat on the wood
Please put a towel down.
WARNING
Covering the heater causes a fire
hazard!
Sauna
light

Publicité