Cleaning, Care And Maintenance - AEG MTE 350 Utilisation Et Installation

Petit chauffe-eau instantané à régulation électronique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 49
Operation - for users and contractors
4. Settings
The appliance heating system switches on automatically
as soon as you open the DHW valve at the tap or activate
the sensor of a sensor tap. The water is heated. The water
temperature can be adjusted at the tap:
For initial flow rate and flow rate limiting, see chapter
"Specification".
Increasing the temperature
» Reduce the flow rate at the tap.
Reducing the temperature
» Open the tap further or add more cold water.
Following an interruption of the water supply
See chapter "Commissioning / Recommissioning".
5. Cleaning, care and
maintenance
» Never use abrasive or corrosive cleaning agents. A
damp cloth is sufficient for cleaning the appliance.
» Check the taps/valves regularly. Limescale deposits
at the spouts can be removed using commercially
available descaling agents.
» Have the electrical safety of the appliance regularly
checked by an electrician.
» Regularly descale or replace the special aerator (see
chapter "Appliance description / Accessories").
32
All manuals and user guides at all-guides.com
6. Troubleshooting
Problem
The appliance will not
start despite the DHW
valve being fully open.
The required tem-
perature is not being
reached.
Cause
No power to the ap-
pliance.
The aerator in the tap
is scaled up or dirty.
The water supply has
been interrupted.
The maximum tem-
perature set inside the
appliance is too low.
The appliance is at its
output limit.
If you cannot remedy the fault, notify your qualified con-
tractor. To facilitate and speed up your enquiry, please
provide the serial number from the type plate (000000 /
0000-00000).
MTE . . .
000000
Model:
E-Nr:
0000-00000
F-Nr:
Remedy
Check the fuses/
MCBs in your fuse
box.
Clean and/or descale
the aerator or replace
the special aerator.
Vent the appliance
and the cold water
inlet line (see chapter
"Settings").
Have your qualified
contractor adjust the
maximum tempera-
ture.
Reduce the flow rate.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mte 440Mte 570Mte 650

Table des Matières