Operating instructions tico 731.1
- Battery powered LCD-Counter
The tico 731.1 is a battery powered LCD-counter with programmable
count input for contact or edge triggering. The following versions are
available:
Totalizer:
Tachometer (1/min):
Time counter (HHHH:MM:SS):
Time counter (HHHHHH.HH):
or with plug in screw terminal e. g. 0 731 101 S
Energy-save mode:
In order to save energy during delivery and stock, the counter is fac-
tory programmed to low-energy mode and the display shows
„SLEEPING". To wake up the counter, just press the front button.
Remark: low energy mode cannot be reactivated.
1. Programming of the COUNT-Input
In order to match your application, the COUNT-Input can be program-
med for high speed (7,5 kHz) or low speed counting (30 Hz attenua-
ted). Positive or negative edge is programmable as well.
NOTE:
The counter leaves the factory with the default value LO NPN
(f
30 Hz and negative edge triggered).
max
To change the count input configuration:
Connect Terminal 4 and 2 (Reset - 0 Volt)
and hold front button for 8 sec
press button shortly
to change values
press button shortly
to change values
press button shortly
to change values
press button longer (> 2 sec)
to confirm the desired value
Count Mode
Zählmodus
Zählmodus
Count Mode
2/6
7
standard
special
0 731 101
0 731 711
0 731 102
0 731 712
0 731 103
0 731 713
0 731 104
0 731 714
Note:
*
low count speed (30 Hz
attenuated) and negative
edge triggered (e.g.
contacts)
Note:
low count speed (30 Hz
attenuated) and positive
edge triggered (e.g.
contacts)
* *
Note:
Maximum count speed
(7,5 kHz) and negative
edge triggered
* *
Note:
Maximum count speed
(7,5 kHz) and positive
edge triggered
*default values
**not applicable to time counters
2. Totalizer version (0 731 101)
Terminal 4 „RESET or Tacho-HOLD" is defined as the Reset-Input.
3. Tachometer version (0 731 102)
The tachometer operates via the gate measuring method. Within the
measuring time of 6 sec, the incoming pulses are counted and recal-
culated in order to display 1/min.
The Terminal 4 „RESET or Tacho-HOLD" is defined as the HOLD-Input
(as long as this Input is active, the actual value in the display is fro-
zen).
4. Time counters version (0 731 103 and 104)
The time counters will count as long as the Count-Input (3) is active.
(this can be a low or a high signal according to programming in
Chapter 1).
Terminal 4 „RESET or Tacho-HOLD" is defined as the Reset-Input.
5. Terminal connection
6. Specifications
Power supply
internal Lithium battery
Battery life
nominal 7 years
Display
LCD, 8-digit, 7 mm
Count input
Terminal 3 „Count"
Active edge
programmable: NPN: negative
(e.g. Contact to ground 0V) or
PNP: positive signal
pulse length: min 70µs or
min 15 ms (if attenuated to 30 Hz )
Count frequency
programmable:
„HI" 7,5 kHz or „LO" 30 Hz (attenuated for
contacts)
Amplitude threshold
< 0,7 V and > 5 V, max 30 VDC
Reset input
Reset with a negative edge on „RESET",
(Terminal 4 bridge to Ground, 0V)
pulse length: min 15 ms
(attenuated to 30 Hz )
Key reset
press front key shortly
Keylock input
Lock front key via bridge between terminals
2 and 1
Mounting
Frontpanel mounted with clamping frame
Front dimension
DIN 48 mm x 24 mm
Panel cut-out
45
Panel thickness
max. 14 mm
Product depth
32 mm
Protection class
front side IP 54
Operating temperature
-10° C to +50°C
Storage temperature
-20° C to +60°C
General rating
DIN EN 61010 part 1,VDE 0411 part 1
Protection class
according to class II
Overvoltage
category II
Contamination
level 2
Sach-Nr. 2 731 020; Version 1210699WBI
+ 0,6
mm x 22
+ 0,3
mm
1 230909 MD