General Information - Napoleon BIPRO 600 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4

General Information

This Gas Barbecue Is Certified Under Canadian And American National Standards, CSA 1.6b-2002 and
ANSI Z21.58b-2002 respectively for Outdoor Gas Grills and should be installed to conform with local codes. In
absence of local codes, install to the current CAN/CSA-B149.1 Propane Installation Code in Canada or to the
National Fuel Gas Code, ANSI Z223.1 in the United States.
If a rotisserie motor is used, it must be electrically grounded in accordance with local codes or, in absence of
local codes, with the current CSA C22.1 Canadian Electrical Code in Canada or the National Electrical Code,
ANSI/NFPA 70 in the United States.
CALIFORNIA PROPOSITION 65: The burning of gas fuel creates by-products, some of which are on the list as
substances known by the State of California to cause cancer or reproductive harm. When cooking with gas,
always ensure adequate ventilation to the unit, to minimize exposure to such substances.
Propane Cylinder Specifications
WARNING!
occur.
A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a
cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance
with the specifications for LP-gas cylinders of the National Standard of Canada, CAN/CSA-b339, Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable or the Specifications
for LP-Gas Cylinders of the U.S. Department of Transportation (D.O.T.). This appliance has been designed for
use with a 20 lb. (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connection device compatible with the connection
for outdoor cooking appliances. The propane cylinder must be provided with a shut-off valve terminating in
a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapor
space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder
shall include a collar to protect the cylinder valve. The cylinder shall incorporate a listed OPD (overfill protection
device). Do not store a spare LP-gas cylinder under or near this appliance. Never fill the cylinder beyond
80 percent full.
Use only the pressure regulator and hose assembly provided with this barbecue. Replacement pressure
regulators and hose assemblies must be specified by the manufacturer. Do not store a spare propane cylinder
on the shelf beneath the barbecue.
The regulator supplies a pressure of 11 inches. water column to the gas grill and has a QCC1 type fitting.
Cylinders to be used with this unit must be supplied with a QCC1 cylinder valve. A QCC1 cylinder has a
positive seating connection, which will not allow gas flow until a positive seal has been achieved. It is also
equipped with an excess flow device. In order to attain full flow to the grill, the valves must be in the off
position when the cylinder valve is turned on.
Gas Hook-Up Instructions
WARNING!
by a qualified installer to local codes.
WARNING!
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instructions. A flexible metal connector is included to simplify the
installation of the unit. Connect this flexible metal connector to the flare fitting on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass through a
wall, floor, ceiling or partition, and is protected from damage. Do not use a hose to connect the unit except to
connect the cylinder regulator to the piping system. It must be connected with rigid pipe, copper tube or an
approved flexible metal connector which complies with Z21.4 /CSA 6.10.
The installation must comply with CAN B149.1 Natural Gas and Propane installation code in Canada, or to the
National Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be sufficiently sized to supply
the BTU/h specified on the rating plate, based on the length of the piping run. If installing a side burner, a
www.napoleongrills.com
If these instructions are not followed exactly, a fire causing death or serious injury may
This grill is designed for non-combustible enclosures only, and must be installed and serviced
Cabinet frame, cabinet, and counter top must be made from non-combustible material.