SECTION 7
Finishing the Installation
1.
Install the filter by fitting the filter into the channel on the hood and sliding it back until it
stops against the back of the hood (Figure 9).
Figure 9
2.
Turn switches to the "OFF" position and restore power. Test that the light and the fan are
operating properly.
3.
If there is any vibration noise, check for the source and try to tighten fasteners.
SECTION 8
Operation
Controls
Your Range Hood is controlled by two remote rocker switches with one controlling the lighting
and the other controlling the exhaust fan. Each rocker switch has three positions, left, center,
and right. For the fan switch, the left position (I) is low speed, while the right position (II) is high
speed. The left position of the light switch (
position (
) illuminates the Main Light only. The center of both switches is the "OFF" position."
Trouble
1. Hood does not operate when the switch is on.
2. Hood is operating, but air moves slower than normal.
3. Hood is making a rattling noise.
6728046 Rev. G 11-16
°
) illuminates the Night Light only, while the right

Troubleshooting Guide

Probable Cause
1a.
A fuse may be blown or a circuit tripped.
1b.
Wiring is not connected properly.
2.
Obstruction in the exhaust ducting.
3a.
Filters are loose.
3b.
Duct connection is loose.
Fuse
Your range hood is equipped with a fuse located inside the wire compartment. To replace the
fuse, turn the fuse cap located next to the wire connector counter clockwise and pull out.
Replace with a Bussman MDA-3 or equivalent 125-Volt, 1.5 Amp Max. fuse. Reinstall the fuse
back into the hood.
SECTION 9
Maintenance
Filters
Grease Filter - Included with your range hood is an aluminum grease filter that should be
washed in hot water with detergent once a month. Reverse the instructions in the "Finishing
the Installation" section of the instructions to remove filter. If the grease filter becomes
damaged, replace with Air King Model GF-08S Grease Filter.
Charcoal Odor Filter - If you have installed an optional combination grease/charcoal filter,
it cannot be washed and must be discarded and replaced when it becomes noticeably dirty,
has stopped filtering the odors, or at least once per year. Replace with Air King Model CF-08S
Combination Odor/Grease Filter.
Changing the Lamp
1.
Remove the lamp cover by squeezing in the sides. The cover is held in place by tension
against the tabs on the hood.
LED Lamp: Remove lamp by gently twisting counterclockwise to release the lamp from
the base. Installation is the reverse of removal. Replace with Air King model AK6LED40 or
a compatible GU24 6 watt LED lamp.
Night Light: Unscrew night light bulb from socket and replace with a 4 watt maximum
type C7 (candelabra base) night light bulb.
Cleaning
CAUTION:
CLEANSERS, ETC., AS THEY MAY DAMAGE THE RANGE HOOD.
1.
Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with
a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry
before restoring power. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
2.
The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over time.
The fan is permanently lubricated and does not require oiling.
CALIFORNIA RESIDENTS ONLY:
WARNING:
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
WARNING:
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE REPRODUCTIVE
TOXICITY.
1a.
1b.
2.
3a.
3b.
www.airkinglimited.com
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT
SERVICE PANEL BEFORE SERVICING THE UNIT.
DO NOT USE GASOLINE, BENZINE, THINNER, HARSH
THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR
THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR
Suggested Remedy
Replace fuse or reset circuit breaker.
Turn off power to unit. Check that all wires are connected.
Check for any obstructions in the ducting including filter.
Turn off power to unit. Check that all filter are securely in place.
Turn off power to unit. Check that duct connection is tight.